Image for Illustrative Purposes Only

Fluke PRV240FS Proving Unit
SKU: FLUPRV240FS
PRV240FS
DESCRIPTION
Features
Specifications
Shipping & Delivery
Fluke PRV240FS Proving Unit
Designed for safety and compliance
Verify your test tool without unnecessary exposure to shock and arc flash. Using the PRV240FS reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification of your tester or multimeter before tests are performed*. Additionally, the PRV240FS also provides ac and dc voltages for other HiZ instruments in your tool box.
A single switch and a set of LEDs indicate functionality of both the FieldSense “no-test-lead” voltage measurement capability, plus standard ac and dc measurements with test leads. This unit is a simple-to-use solution for complying with TBT verification of your test tools.
*PPE is still needed for absence of voltage testing when appropriate.
“Test Before Touch”
Fluke’s PRV240FS allows you to “Test Before Touch” (TBT), which involves testing your T6 against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.
Discover the Fluke PRV240FS Proving Unit at Mektronics Australia – your trusted source for quality tools and equipment!
Reduce your risk of shock and arc flash by validating the functionality of test tools without placing yourself in a potentially hazardous electrical environment.
• Prove functionality of the FieldSense measurement on the T6 electrical testers
• Source both ac and dc steady-state voltage (supplies 240 V dc/ac).
• Compatible with high impedance multimeters or clamp meters.
• Voltage is sourced through a central hub designed to test the T6 FieldSense open fork, as well as through recessed contacts that are activated when test probes are inserted to avoid accidental contact
• Includes TPAK magnetic hanging strap
• Long battery life—2000 tests per set of four AA batteries (10 second test average)
- SAFETY RATING: IEC61010-1, IEC61010-2-030
Output voltage |
240 V ac rms or dc |
± 10 % ≥ 1 MΩ |
|
LED power indicator |
Turns on when output voltage is present |
||
Battery |
4 x AA Alkaline batteries NEDA 15 A IEC LR6 |
||
Battery life |
1100 (10-second duration) test cycles with >1 MΩ load |
||
Operating temperature |
-10 °C to +50 °C |
||
Operating humidity |
0 % to 90 % (0 °C to 35 °C) |
0 % to 70 % (35 °C to 55 °C) |
|
Operating altitude |
2000 m |
||
Dimensions |
11.7 cm x 7.4 cm x 4.5 cm (4.6 in x 2.9 in x 1.75 in) |
||
Weight |
0.32 kg (12 oz) includes batteries |
||
Safety |
IEC61010-1, IEC61010-2-030 |
||
Warranty |
One-year |
||
Electromagnetic Compatibility (EMC) |
IEC 61326-1: Controlled Electromagnetic Environment |
||
US (FCC) |
47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103 |
||
Korea (KCC) |
Class A Equipment (Industrial Broadcasting & Communication Equipment) |
||
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.