Image for Illustrative Purposes Only
Fluke BT510 Battery Analyzer
SKU: FLUBT510/APAC
BT510/APAC
DESCRIPTION
Features
Inclusions
Specifications
Shipping & Delivery
Fluke BT510 Battery Analyzer
Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level of ease-of-use in battery testing.
- The ideal test tool for maintenance, troubleshooting and performance testing of individual stationary batteries and battery banks used in critical battery back-up applications
- The intuitive user interface, compact design and rugged construction ensure optimum performance, test results and reliability
- Covers a broad range of battery test functions ranging from DC voltage and resistance tests to full condition testing using automated string function testing and the test probe integrated infra-red temperature measurement system
- Designed for measurements on stationary batteries of all types.
Discover the Fluke BT510 Battery Analyzer at Mektronics Australia – your trusted source for quality tools and equipment!
- Battery Voltage – During the internal resistance test, Fluke Battery Analyzers also measure the voltage of the battery under test
- Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
- Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
- Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts, users can configure a profile for the task for data management and report generation
- Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
- Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string. Once the measurements are completed Fluke Battery Management Software version 1.0.69 can now report the strap resistance for a battery string or historical data over time.
- AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
- AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured
- Fluke Battery Management Software – Easily import data from the Product to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used for comparison and trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports
- Comprehensive logging – All measured values are automatically captured during testing and can be reviewed on the instrument before downloading for on the-go analysis
- Optimized user interface – Quick, guided setup ensures you're capturing the right data every time
- Battery life – 7.4 V 3000 mAh lithium-ion battery for more than eight hours continuous operation.
- USB port – For fast data download to supplied data analysis and report management application software.
- Highest safety rating in the industry – CAT III 600 V, 1000 V dc max. rated for safe measurements all around the battery power supply equipment.
Fluke Battery Analyzers allow you to quickly and easily define upper and lower measurement thresholds or tolerance ranges. During the testing process, measured values are automatically compared to the predefined threshold levels producing a PASS, FAIL or WARN indication after each measurement. A maximum of 10 sets of thresholds can be stored and threshold indications are determined based on the following criterion:
| Voltage | Resistance | |||
| > Voltage Lower | < Voltage Lower | < Reference | > Reference and < Reference x (1+Warning %) |
Reference x (1+Fail) |
| Pass | Fail | Pass | Warning | Fail |
Fluke Battery Management Software allows you to quickly and easily import data from the battery analyzer to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used compare results, switch results between conductance and resistance readings and perform trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports.
- Quick view saved readings
- Profile management
- Histogram of a battery string with end user defined threshold
- Historical trend data of batteries
- Multiple rounds of discharge voltage
- Quick Report Generation
- Upgrade Fluke Battery Analyzer firmware
- Switch measurement results between conductance and resistance readings
- Battery analyzer
- 4-wire test pin (set)
- BTL10 Basic Test Lead (set)
- TL175 TwistGuard™ Test Leads with adapter
- BP500 lithium-ion battery
- BC500 AC charger
- mini-USB cable
- Shoulder strap
- Belt strap
- Magnetic hanging strap
- FlukeView® Battery Management Software
- Soft carrying case
- Spare fuses (2)
- Zero Ohm Calibration Resistor
| Functions | Range | Resolution | Accuracy | BT510 | BT520 | BT521 |
| Battery Resistance / Strap Resistance1 | 3 mΩ | 0.001 mΩ | 1% + 8 | â— | â— | â— |
| 30 mΩ | 0.01 mΩ | 0.8% + 6 | â— | â— | â— | |
| 300 mΩ | 0.1 mΩ | 0.8% + 6 | â— | â— | â— | |
| 3000 mΩ | 1 mΩ | 0.8% + 6 | â— | â— | â— | |
| VDC | 6 V | 0.001 V | 0.09% + 5 | â— | â— | â— |
| 60 V | 0.01 V | 0.09% + 5 | â— | â— | â— | |
| 600 V | 0.1 V | 0.09% + 5 | â— | â— | â— | |
| 1000 V | 1 V | 0.09% + 5 | â— | |||
| VAC (45 Hz to 500 Hz with 800 Hz filter) | 600 V | 0.1 V | 2% + 10 | â— | â— | â— |
| Frequency (displayed with VAC and AAC)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | â— | â— | â— |
| AC voltage ripple (20 KHz Max) | 600 mV | 0.1 mV | 3% + 20 | â— | â— | â— |
| 6000 mV | 1 mV | 3% + 10 | â— | â— | â— | |
| ADC/AAC (with accessory Fluke i410) | 400 A | 1 A | 3.5% + 2 | â— | ||
| Temperature | 0°C to 60°C | 1°C | 2°C (4°F) | â— | ||
| Meter mode | 999 records for each measurement position with time stamp | |||||
| Sequence mode | Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp | |||||
| 1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz. 2. Trigger level VAC: 10 mV, AAC: 10 A |
||||||
| Measurement Modes | BT510 | BT520 | BT521 | |||
| Resistance (mΩ) | â— | â— | â— | |||
| Battery voltage | â— | â— | â— | |||
| Voltage DC | â— | â— | â— | |||
| Voltage AC and frequency (Hz) | â— | â— | â— | |||
| Ripple volt | â— | â— | â— | |||
| Temperature of negative battery post | â— | |||||
| DC and AC current (and frequency) | â— | |||||
| DMM mode | â— | â— | â— | |||
| Sequence mode | â— | â— | â— | |||
| Discharge measurement mode | â— | â— | â— | |||
| Automatic measurement save | â— | â— | â— | |||
| Wireless commumcation | â— | |||||
| Memory view | â— | â— | â— | |||
| General Specifications | ||||||
| Size (H x W x D) | 22 x 10.3 x 5.8 cm (9 x 4 x 2 in) | |||||
| Weight | 850 g (1.9 lb) | |||||
| Screen dimensions | 7.7 x 5.6 cm (3 x 2.2 in) | |||||
| Interface | USB mini | |||||
| Warranty | 3 years | |||||
| Environment Specifications | ||||||
| Operating temperature | 0°C to 40°C | |||||
| Storage temperature | -20°C to 50°C | |||||
| Lithium-ion battery charging temperature | 0°C to 40°C | |||||
| Operating humidity | Non-condensing (10°C) | |||||
| ≤ 80% RH (at 10°C to 30°C) | ||||||
| ≤ 75% RH (at 30°C to 40°C) | ||||||
| Operating altitude | Sea level to 2000 meters | |||||
| Storage altitude | Sea level to 12,000 meters | |||||
| IP rating | IP40 | |||||
| Radio | FCC Class A | |||||
| Vibration requirements | MIL-PRF-28800F: Class 2 | |||||
| Drop test requirements | 1 meter | |||||
| Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||||
| Safety compliance | 600 V CAT III | |||||
| EMC | IEC 61326 | |||||
| ROHS | China, Europe | |||||
| Protection class 2 | Pollution Degree II | |||||
| Battery compliance | UN38.3 | |||||
| UL2054 | ||||||
| IEC62133 | ||||||
| 2 G per IEC68-2-26, 25 G, and 29 | ||||||
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.