The BC430/830 is a universal mains-power adapter (the Adapter or Product) for measurement, control, and laboratory equipment. The Adapter is intended for operating and charging the Fluke 430-Series Power Quality Analyzers and 120B-Series ScopeMeter Test Tool. The Adapter is based on the switched-mode concept for high efficiency and low stand-by power consumption, and complies with level-VI requirements. It operates in a wide range of input voltages from 100 Vac up to 240 Vac nominal.
A universal set of mains cords is included to make the Adapter suitable for most types of mains outlet.
Discover the Fluke BC430/830 Universal Mains-Power Adapter at Mektronics Australia – your trusted source for quality tools and equipment!
- Input
- Nominal input voltage ................ 100 Vac to 240 Vac, ±10 %
- Input current ............................... 0.35 A at max. load Nominal
- input frequency ............ 50/60 Hz ±10 %
- Mains inlet .................................. IEC 60320-1 type C8
- Input power, no load................... <0.1 W (@ 115 / 230 Vac)
- Output
- Output voltage............................ 18 Vdc ±5 %
- Output current ............................ 0 mA to 840 mA
- Output cable length .................... 2 m (6.5 ft)
- Output connector ....................... 5 mm outer diameter, per DIN45232
- Output polarity............................ Inner contact negative, outer contact positive
- Physical characteristics
- Dimensions of main unit............. 79 mm x 149 mm x 49 mm
- Housing material ........................ Heat resistant ABS
- Color (housing and cable) ..........Black
- Weight ........................................ 0.35 kg
- Ingress Protection ...................... IEC 60529, IP40
- Environmental
- Operating temperature ............... 0 °C to 50 °C (32 °F to 122 °F), up to 90 % rel. humidity, no condensation
- Storage temperature ..................-40 °C to +70 °C, 10 to 95 % rel. humidity
- Max. altitude............................... 2000 m (6562 ft) above sea-level
- Included accessories
- Power cord ................................. Universal set of 2-wire cords
- Mains cord length....................... 1.8 m (6 ft), male to female
- Power plug adapters .................. US-style, UK-style, European, Japanese, Chinese/Australian, Brazilian
- Safety ............................................. IEC 61010-1, IEC 61010-2-030: CAT IV 600 V, Pollution Degree 2
- Electromagnetic
- Compatibility (EMC) ..................... IEC 61326-1: Industrial Electromagnetic Environment
- BC430/830 Switch Mode Power Adapter (main unit) with dc cable
- Universal set of 2-wire mains cords with male and female connector
At delivery of the Adapter, make sure that the shipment is complete and all items are undamaged. Contact your supplier if you see any damage.
Operation- The power cord connects the Adapter to the mains system. Do not block access to the power cord and power plug, these must remain accessible to the user at all times. The Adapter is not equipped with a power switch. Disconnect the mains plug from the mains system when not in use. In case the Adapter is damaged or any damage is suspected, disconnect from the mains system and have qualified service personnel inspect the Adapter before reconnecting to the mains system again.
- To use:
- Connect the mains cord to the Adapter.
- Connect the power plug to the mains system.
- Connect the dc plug to the test tool.
- For continuous operation and recording with the test tool, keep the power adapter connected.
- The Adapter operates and charges the test tool from local line voltage. Any power supply connected to the test tool introduces a certain capacitive coupling between the test tool and ground through the power supply circuitry. This capacitive coupling can affect test tool measurements.
- The Adapter is equipped with dedicated decoupling networks to reduce possible effects of such capacitive coupling during measurements.
- For an optimal decoupling from ground, especially to make low-level measurements, Fluke recommends that you work in battery-operated mode without any power adapter connected.
Note Always fully charge the test tool battery before storage.
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.