Product overview:
The 87V MAX contains all the trusted features of the most popular DMM used today, the Fluke 87V, plus much more.
Withstands drops up to 4-meters (13 feet)
Fluke's most rugged digital multimeter. The 87V MAX is built with an industrial strength case and a removable holster. The holster doubles as a test probe holder for one-handed operation.
IP67 rated
Fully waterproof and dust proof, to work reliably in all the places that you need to work.
Withstands heat and cold
The meter has an extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C.
Other product highlights
True-rms ac voltage and current for accurate measurements on non-linear signals
Measure up to 1000 V ac and dc
Measure up to 10 A (20 A for 30 seconds)
Frequency to 200 kHz
Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
Min/Max/Average recording, plus 250 μs Peak min-max to capture variations automatically
Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment
Large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility
Hi resolution 19,999 count display mode
Long battery life (800 hours)
Comparison "“ 87V MAX and 87V
|
87V MAX |
87 V |
|
|
IP Rating |
IP 67 |
IP 30 |
|
Battery life |
800 hours |
400 hours |
|
Drop test |
4 meters |
3 meters |
|
Backlit keypad |
Yes |
No |
|
TwistGuard™ test leads |
Yes |
No |
|
True-rms readings |
ac |
ac |
|
Basic dc accuracy |
0.05% |
0.05% |
|
Voltage ac/dc |
1000 V |
1000 V |
|
Current ac/dc |
10 A |
10 A |
|
Resistance |
50 MΩ |
50 MΩ |
|
EN61010-1 CAT III |
1000 V |
1000 V |
|
EN61010-1 CAT IV |
600 V |
600 V |
|
Warranty (years) |
Limited lifetime |
Limited lifetime |
Discover the Fluke 87V MAX True-rms Digital Multimeter at Mektronics Australia – your trusted source for quality tools and equipment!
Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
Waterproof, dustproof IP67 case for the most extreme work sites
Premium TL175 TwistGuard™ test leads
Double the battery life of the 87V (up to 800 hours); backlit keys for dark environments
Removable holster with test lead storage
TL175 TwistGuard ® test leads
AC175 Alligator clips
80BK-A temperature probe
Three AA batteries (installed)
|
Electrical Specifications |
||
|
DC Voltage |
Range |
0.1 mV to 1000 V |
|
Accuracy |
±(0.05% + 1) |
|
|
Maximum resolution |
0.1 mV |
|
|
AC Voltage |
Range |
0.1 mV to 1000 V |
|
Accuracy |
±(0.7% + 4) true-rms |
|
|
AC bandwidth |
20 kHz with low pass filter; 3 dB @ 1 kHz |
|
|
Maximum resolution |
0.1 mV |
|
|
DC Current |
Range |
0.1 μA to 10 A (20 A for 30 seconds maximum) |
|
Amps accuracy |
±(0.2% + 2) |
|
|
Maximum resolution |
0.1 µA |
|
|
AC Current |
Range |
0.1 μA to 10 A (20 A for 30 seconds maximum) |
|
Amps accuracy |
±(1.0% + 2) true-rms |
|
|
Maximum resolution |
0.1 µA |
|
|
Resistance |
Range |
0.1 Ω to 50 MΩ |
|
Accuracy |
±(0.2% + 1) |
|
|
Maximum resolution |
0.1 Ω |
|
|
Capacitance |
Range |
0.01 nF to 9999 μF |
|
Accuracy |
±(1% + 2) |
|
|
Maximum resolution |
0.01 nF |
|
|
Frequency |
Range |
0.5 Hz to 199.99 kHz |
|
Accuracy |
±(0.005% + 1) |
|
|
Maximum resolution |
0.01 Hz |
|
|
Duty cycle |
Maximum duty cycle |
99.9% |
|
Accuracy |
±(0.2% per kHz + 0.1%) |
|
|
Maximum resolution |
0.1% |
|
|
Temperature measurement range |
"“200.0 °C to 1090 °C "“328.0 °F to 1994.0 °F excluding probe |
|
|
80 BK temperature probe |
"“40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater "“40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
|
|
Conductance |
Maximum conductance |
60.00 nS |
|
Accuracy |
±(1.0% + 10) |
|
|
Maximum resolution |
0.01 nS |
|
|
Diode test |
Range |
2 V |
|
Resolution |
0.001V |
|
|
Accuracy |
±(1% + 1) |
|
|
Diagnostics and data storage |
Peak Min/Max |
250 μS |
|
Min/Max/Avg |
Yes |
|
|
Reading hold/Auto (Touch) Hold |
Yes |
|
|
Relative reference |
Yes |
|
|
Display |
Digital |
6000 counts updates 4/second 19,999 counts in high"“resolution mode |
|
Analog bar graph |
32 segments, updates 40/second |
|
|
Backlight |
Two level |
|
|
Low pass filter (VFD measurements) |
Yes |
|
|
Input Alert™ |
Yes |
|
|
Safety Specifications |
||
|
Safety rating |
IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
|
|
Agency approvals |
CE, CSA |
|
|
Mechanical and General Specifications |
||
|
IP rating |
IEC 60529: IP67 |
|
|
Power |
Three AA batteries. 800 hours typical, without backlight |
|
|
Size |
6.0 x 10.1 x 21.5 cm (with holster) |
|
|
Weight |
698.5 g (with holster) |
|
|
Warranty |
Limited lifetime |
|
|
Environmental Specifications |
||
|
Operating temperature |
-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C |
|
|
Storage temperature |
-40 °C to + 60 °C |
|
|
Humidity (without condensation) |
0% "“ 90% (0 °C "“ 35 °C) 0% "“ 70% (35 °C "“ 55 °C) |
|
|
Operating altitude |
2000 m |
|
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.