Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
Fluke 323 True-rms Clamp Meter.Rugged. Reliable. Precise.
- 400 A AC current measurement.
- 600 VAC and DC voltage measurement.
- True RMS AC voltage and current for accurate measurements on non-linear signals.
- Resistance measurement up to 40 kΩ with continuity detection.
- Slim, ergonomic design.
- CAT IV 300V/CAT III 600 V safety rating.
Fluke 1AC II VoltAlert™ Voltage Detector
- Voltbeat™ technology and continuous self-test, so always know it’s working.
- Upon detection, tip glows and beeper sounds.
- Voltage detection of 90 to 1000 VAC.
- CAT IV 1000 V for added protection.
- Fluke 62 MAX+ IR Thermometer
- Fluke 323 True-rms Clamp Meter
- Fluke 1AC II VoltAlert Voltage Detector
- C115 Soft Case
Fluke 62 MAX+ Infrared Thermometer
| Specifications | ||
| Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
| Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 |
|
| Response time (95%) |
< 300 ms (95% of reading) |
|
| Spectral response | 8 to 14 microns | |
| Emissivity | 0.10 to 1.00 | |
| Optical resolution | 12:1 (calculated at 90% energy) | |
| Display resolution | 0.1°C (0.2°F) | |
| Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
| Power | AA battery | |
| Battery life | 8 hours with laser and backlight on | |
| Physical Specifications | ||
| Weight | 255 g (8.99 oz) | |
| Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
| Operating temperature | 0°C to 50°C (32°F to 122°F) | |
| Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
| Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
| Operating altitude | 2000 meters above mean sea level | |
| Storage altitude | 12,000 meters above mean sea level | |
| IP rating | IP 54 per IEC 60529 | |
| Drop test | 3 meters | |
| Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
| EMC | EN 61326-1:2006 EN 61326-2:2006 | |
| Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
| Laser safety | FDA and EN 60825-1 Class II | |
Fluke 323 True RMS Clamp Meter
| Specifications | ||
| AC current | Range | 400.0 A |
| Accuracy | 2% ±5 digits (45 Hz to 65 Hz) 2.5% ±5 digits (65 Hz to 400 Hz) |
|
| AC voltage | Range | 600.0 V |
| Accuracy | 1.5% ±5 digits | |
| DC voltage | Range | 600.0 V |
| Accuracy | 1.0% ±5 digits | |
| Resistance | Range | 400.0 Ω/ 4000 Ω |
| Accuracy | 1.0% ±5 digits | |
| Continuity | ≤ 70 Ω | |
| AC response | True-rms | |
| Data hold | Yes | |
| Size | H x W x D (mm) | 207 x 75 x 34 |
| Max wire diameter | 30 mm (600 MCM) | |
| Weight | 265 g | |
| Category rating | CAT III 600 V CAT IV 300 V |
|
| Warranty | Two-year | |
Fluke 1AC-II VoltAlert
| Specifications | ||
| Operating principle | Senses the steady state electrostatic ï¬eld produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. | |
| Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model | |
| Detector tip style | Blade or round, depending on model | |
| Light source | One high intensity red LED | |
| Agency approvals | c CSA us, CE, C-Tick | |
| Safety rating | 1000 V, CAT IV | |
| IP rating | IP 40 | |
| Operating temperature | -10°C to 50°C | |
| Operating humidity ranges | 0% to 95% | (0°C to 30°C) |
| 0% to 75% | (30°C to 40°C) | |
| 0% to 45% | (40°C to 55°C) | |
| Operating altitude | 3000 meters | |
| Batteries | 2 AAA alkaline batteries included | |
| Product does not respond to random electrostatic discharge. | ||
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.