The Fluke 572-2 High-Temperature Infrared Thermometer is the one product you can use in high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the 572-2 allows you to carry the most trusted name in test tools anywhere you need accurate, high-temperature and high distance-to-spot measurements.
With a straight-forward user interface and soft-key menus, the Fluke 572-2 makes even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Discover the Fluke 572-2 High Temperature Infrared Thermometer at Mektronics Australia – your trusted source for quality tools and equipment!
- Measure -30 °C to 900 °C (-22 °F to 1652 °F)
- 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
- Multi-language interface (user select)
- Current Temperature plus MAX, MIN, DIF, AVG temperature displays
- Compatible with standard mini-connector K-type thermocouples, including ones you already own and have installed
- Adjustable emissivity and predefined emissivity table
- Infrared and thermocouple temperature on backlit display
- Last reading Hold (20 seconds)
- High and low temperature alarm
- Data storage and review (99 data sets)
- Tripod mount
- 12 or 24 hour clock
- USB 2.0 computer interface cable
- FlukeView® Forms documenting software
- Two-year warranty
Model Name |
Fluke 572-2 High Temperature Infrared Thermometer |
Fluke 572-2 |
High-Temperature Infrared Thermometer Includes:
|
Infrared Measurements | |
Infrared temperature range | -30°C to 900°C (-22°F to 1652°F) |
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) | ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater |
≥ -10°C to < 0°C: ±2°C | |
< -10°C: ±3°C | |
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater | |
≥ 14°F to < 32°F: ±4°F | |
< 14°F: ±6°F | |
IR repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
Display resolution | 0.1°C / 0.1°F |
Distance: Spot | 60:1 (calculated at 90% energy) |
Minimum spot size | 19 mm |
Laser sighting | Offset dual laser, output < 1 mW |
Spectral response | 8 μm to 14 μm |
Response time (95%) | < 500 ms |
Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Contact Measurements | |
K-type thermocouple input temperature range | -270°C to 1372°C (-454°F to 2501°F) |
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) | < -40°C: ±(1°C + 0.2° / 1°C) |
≥ -40°C: ±1% or 1°C, whichever is greater | |
< -40°F: ±(2°F + 0.2° / 1°F) | |
≥ -40°F: ±1% or 2°F, whichever is greater | |
K-type thermocouple | 0.1°C / 0.1°F |
K-type thermocouple repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
Measurement Options | |
Hi/Low alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Switchable celsius and fahrenheit | Yes |
Backlight | Two levels, normal and extra bright for darker environments |
Probe input | K-type thermocouple simultaneous display of probe and IR temperature |
Trigger lock | Yes |
Data storage | 99 points |
Display | Dot matrix 98 x 96 pixels with function menus |
Communication | USB 2.0 |
K-Type Thermocouple Specifications | |
Measurement range (bead probe) | -40°C to 260°C (-40°F to 500°F) |
Accuracy | ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |
Cable length | 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
General Specifications | |
Safety and compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
Storage temperature | -20°C to 60°C (-4°F to 140°F) |
Relative humidity | 10% to 90% RH non-condensing up to 30°C (86°F) |
Operating altitude | 2000 meters above mean sea level |
Weight | 0.322 kg (0.7099 lb) |
Power | 2 AA batteries |
Battery life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on) |
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.