DESCRIPTION
Features
Includes
DESCRIPTION
Specifications
Shipping & Delivery

Fluke 561 HVAC Infrared & Contact Thermometer

IR Thermometer with K-type thermocouple capability

Lighten up your toolbox. The Fluke 561 IR and contact thermometer, combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both infrared and contact temperature, replacing several other test tools. It’s fast, efficient, and easy to use, saving you valuable time and effort.

With the Fluke 561 infrared thermometer, you can also take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor-leave your ladder in the truck. You can use the Fluke 561’s handy flexible pipe probe, or plug in any industry standard type K mini connector thermocouple probe you already own to take super-heat or internal temperatures.

Discover the Fluke 561 HVAC Infrared & Contact Thermometer at Mektronics Australia – your trusted source for quality tools and equipment!

  • IR thermometer for quick measurements up close, or at a distance, without a ladder
  • Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
  • Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
  • Single-point laser sighting
  • Temperature range of -40 °C to 550 ° C (-40 °F to 1022 °F) covers most industrial and residential applications
  • Easy emissivity adjustment (Lo, Med, Hi) for measuring pipes and other shiny materials more accurately
  • Lightweight (just 12 ounces/340 grams) and portable
  • Very easy to use
  • Efficient – no need to shut down equipment when making IR measurements
  • MIN, MAX, and DIF functions help you quickly identify problems
  • Scan large areas or small objects quickly and efficiently
Model Name

Fluke 561 HVAC Infrared & Contact Thermometer

Fluke 561 Includes:
  • 561 IR thermometer
  • K-Type thermocouple
  • Fabric hook-and-loop fastener pipe probe
  • Hard carrying case
  • 2 AA batteries
  • Users manual
General Specifications
Temperature -40 to 550°C (-40 to 1022°F)
Display resolution 0.1°C (0.1°F) of reading
D:S (distance to spot size) 12:1
Easy emissivity selector Adjustable with three settings:
Low (0.3), medium (0.7). high (0.95)
Display accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)] ±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C / 32°F, ±1°C (±2°F) ±0.1°/1°
Response time 500 mSec (95% of reading)
Repeatability ±0.5% of reading or ±1°C (±2°F), whichever is greater
Spectral response 8 µm to 14 µm
Laser sighting Single point laser
Laser shutoff Laser turns off above ambient temperature of 40°C (104°F)
Laser power Class 2(II) operation; Output < 1 mW, wavelength 630-670 nm
Relative humidity 10% to 90% RH non-condensing, at < 30°C (86°F)
Power, battery life 2 AA batteries (alkaline or NiCD)
Battery life 12 hours
Display hold 7 seconds
Backlit display Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options
Warranty 2 years
Operating temperature 0°C to 50°C (32°F to 120°F)
Storage temperature -20°C to 65°C (-25°F to 150°F)
MAX, MIN, DIF temperatures Yes
Thermocouple Type K mini adapter input Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range.
Thermocouple Type K fabric hook-and-loop fastener pipe probe Yes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F)
HVAC measurement guide Yes


SHIPPING

A delivery and handling charge applies to all orders with the exception of back-ordered items.

Unless otherwise required by Buyer, Seller will make transport arrangements as follows:

For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods

For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.

Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.

Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.

DELIVERY TIME

All quoted delivery or consignment dates are estimates only, given without engagement.

Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.

Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer

a) in the event of a delay in consignment or delivery of goods: or

b) in the event of non delivery.

Goods offered ex-stock by Seller are subject to prior sale.

In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.