Image for Illustrative Purposes Only
Fluke Logo

Fluke 51 II Handheld Digital Probe Thermometer

SKU: FLU51-250HZ

51-250HZ

$718.00

EX. GST
$789.80
INC GST
Out of Stock: Available to Order

own it from $10 a week with Group 2 Copy Created with Sketch.

DESCRIPTION
Features
Features
Specifications
Shipping & Delivery

Fluke 51 II Handheld Digital Probe Thermometer

The Fluke 51 II single input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 51 II to measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.

Discover the Fluke 51 II Handheld Digital Probe Thermometer at Mektronics Australia – your trusted source for quality tools and equipment!

  • Single Input digital thermometer for lab, QA, process calibration, food safety and HVAC
  • Measures J, K, T, and E-type thermocouples
  • Presents results in °C, °F, or Kelvin (K) on a large backlit display
  • Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
  • Easy-to-access battery door that allows replacing the battery without breaking the calibration seal
  • Comes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty
  • Powered by three, standard AA batteries -30-
  • Includes an electronic offset function that compensates for thermocouple errors to maximize overall accuracy
  • Handles temperatures up to 900°C (1600°F)
  • Provides a user-friendly front panel that is easy to set up and operate
  • Offers sleep mode to increase battery life: 1000-hour battery life typical
Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C]1
R and S-type: ±[0.05% + 0.4°C]1
Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C]1
T-type: ±[0.50% + 0.3°C]
Temperature J-type -210°C to 1200°C
K-type -200°C to 1372°C
T-type -250°C to 400°C
E-type -150°C to 1000°C
N-type -200°C to 1300°C1
R and S-type 0°C to 1767°C1
Temperature scale ITS-90
Applicable standards NIST-175
Display resolution 0.1°C, 0.1 K < 1000
1°C, 1 K ≥ 1000
1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.
Environmental Specifications
Operating temperature -10°C to 50°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 0% to 90%; 0°C to 35°C
0% to 70%; 0°C to 50°C
Safety Specifications
Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Agency approvals CE, CSA, TÜV (pending)
Mechanical and General Specifications
Size (L x W x D) 173 x 86 x 38 mm
Weight 400 g
Batteries 3 AA batteries; typical 1000-hour life

SHIPPING

A delivery and handling charge applies to all orders with the exception of back-ordered items.

Unless otherwise required by Buyer, Seller will make transport arrangements as follows:

For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods

For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.

Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.

Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.

DELIVERY TIME

All quoted delivery or consignment dates are estimates only, given without engagement.

Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.

Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer

a) in the event of a delay in consignment or delivery of goods: or

b) in the event of non delivery.

Goods offered ex-stock by Seller are subject to prior sale.

In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.