Fluke 320x240 Infrared Camera 9HZ TiS60+
Fluke 320x240 Infrared Camera 9HZ TiS60+
Fluke 320x240 Infrared Camera 9HZ TiS60+
Image for Illustrative Purposes Only
Fluke Logo

Fluke 320x240 Infrared Camera 9HZ TiS60+

SKU: FLUFLK-TIS60+9HZ

FLK-TIS60+9HZ

$7,119.00

EX. GST
$7,830.90
INC GST
In Stock

Order before 2pm today for same day dispatch of up to units from our Sydney warehouse.

own it from $10 a week with Group 2 Copy Created with Sketch.

DESCRIPTION
Features
Inclusions
Specifications
Shipping & Delivery

Fluke 320x240 Infrared Camera 9HZ TiS60+

Boost you or your team's performance with 320 x 240 resolution. Infrared images taken with the TiS60+ capture smaller temperature differences from further away. If you are new to thermal imaging or if your camera is being used by a team with varying levels of thermal imaging experience, the TiS60+ offers fixed focus with the ability to capture quality images from further.

The TiS60+ allows you to see things that are invisible to the eye and reveal problems that cannot be detected with other technologies. It is a simple to use, dependable tool that the team can rely on.

  • Easy to use fixed focus

  • 3.5 inch LCD screen

  • One-handed image capture, review and save capability

  • Fluke Connect™ compatibility for sharing wirelessly

Often the next big challenge with infrared images is to make sure that the images taken by the team can quickly be added to work orders. The TiS60+ features IR Photo Notes making this easy. They give the camera operator a simple way to add pictures associated with the image documenting the equipment name or the room location associated with the thermal image so that the person creating the work order can send the technicians to the right location for repairs.

Be prepared with everything you need to establish a baseline for your equipment, establish a preventive maintenance program and set standard work. The Fluke TiS60+ gives you the thermal data needed to get the job done.

Discover the Fluke 320x240 Infrared Camera 9HZ TiS60+ at Mektronics Australia – your trusted source for quality tools and equipment!

  • 320 x 240 resolution

  • 2 meter drop test

  • IR Fusion™ technology for context

  • Fixed focus

  • Measure up to 400 °C

  • Thermal imager

  • AC power supply (including universal AC adapters)

  • Two-bay smart battery charger

  • Two rugged lithium ion smart batteries

  • USB cable

  • 4 GB micro SD card

  • Rugged hard carrying case with soft transport bag and adjustable hand strap

  • Available by free download: Fluke Connect™ software and user manual

Key features

IFOV (spatial resolution)

1.86 mRad, D:S 532:1

Infrared resolution

320 x 240 (76,800 pixels)

Field of view

34.1 °H x 25.6 °H

Focus system

Fixed

Minimum focus distance

46 cm (18 in)

Ruggedized display

3.5 inch (8.9 cm landscape) 320 x 240 LCD

Ergonomic design

Designed for one-handed use

Temperature measurement

Temperature range (not calibrated below -10 °C)

-20 °C to 400 °C (-4 °F to 752 °F)

Accuracy

± 2 °C or 2 % (at 25 °C nominal, whichever is greater)

Thermal sensitivity (NETD)

≤ 0.045 °C at 30 °C target temp (45 mK)

On-screen emissivity correction

Yes (both value and table)

On-screen reflected background temperature compensation

Yes

On-screen transmission correction

No

Wireless connectivity

Wireless connectivity

Yes, to PC, iPhone ® and iPad ® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available)

Fluke™ Connect app compatible

Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing

Fluke Connect Assets optional software

Yes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location

IR Fusion ® technology

IR Fusion ® technology

Yes

AutoBlend™ mode

Yes

Picture-In-Picture (PIP)

Yes

Built-in digital camera (visible light)

5MP

Level and span

Level and span

Smooth auto and manual scaling

Fast auto-rescale in manual mode

Yes

Minimum span (in manual mode)

2.5 °C (4.5 °F)

Minimum span (in auto mode)

5 °C (9.0 °F)

Data storage and image capture

Extensive memory options

Internal 4GB memory and 4GB micro SD card

Image capture, review, save mechanism

One-handed image capture, review, and save capability

Image file formats

Non-radiometric BMP or JPEG or fully-radiometric is2

Memory review

Yes

Software

Fluke Connect desktop software - full analysis and reporting software with access to the Fluke Connect system

Analyze and store radiometric data on a PC

Yes

Export file formats with Fluke Connect software

is2, BMP, GIF, JPEG, PNG, TIFF

Voice annotation

60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset required (sold separately)

IR-PhotoNotes

Yes - 3 images

Auto capture (temperature and interval)

Yes

Battery

Batteries (field-replaceable, rechargeable)

Two lithium ion smart battery pack with five-segment LED display to show charge level

Battery life

4 hours continuous use per battery pack

Battery charging time

2.5 hours to full charge

Battery charging system

Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter

AC operation

AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)

Power saving

User selectable

Color palettes

Standard palettes

8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted

Ultra contrast palettes

8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra

General specifications

Laser pointer

Yes

Frame rate

< 9 Hz or 30 Hz

Color alarms

High temperature, low temperature, isotherms (within range)

Infrared spectral band

7.5 μm to 14 μm

Operating temperature

-10 °C to +50 °C (14 °F to 122 °F)

Storage temperature

-20 °C to +50 °C (-4 °F to 122 °F) without batteries

Relative humidity

10 % to 95 %, non-condensing

Center-point temperature measurement

Yes

Spot temperature

Hot and cold spot markers

User-definable spot markers

3

User defined measurement boxes

Expandable-contractible measurement box

Hard case

Rugged hard carrying case with soft transport bag, including adjustable strap

Safety standards

IEC 61010-1: Overvoltage category II, Pollution Degree 2

Electromagnetic combability

IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A

Australian RCM

RCM IEC 61326-1

US FCC

EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3

Vibration

2G, IEC 68-2-6

Shock

25G, IEC 68-2-29

Drop

Engineered to withstand 2 meter (6.5 feet) drop

Sized (H x W x L)

26.7 cm x 10.1 cm x 14.5 cm (10.5 in x 4.0 in x 5.7 in)

Weight (battery included)

0.72 kg (1.6 lb.)

Enclosure rating

IP54 (protected against dust, limited ingress; protection against water spray from all directions)

Warranty

Two-years (standard)

Recommended calibration cycle

Two-years (assumes normal operation and normal aging)

Supported languages

Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

RoHS compliant

Yes



SHIPPING

A delivery and handling charge applies to all orders with the exception of back-ordered items.

Unless otherwise required by Buyer, Seller will make transport arrangements as follows:

For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods

For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.

Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.

Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.

DELIVERY TIME

All quoted delivery or consignment dates are estimates only, given without engagement.

Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.

Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer

a) in the event of a delay in consignment or delivery of goods: or

b) in the event of non delivery.

Goods offered ex-stock by Seller are subject to prior sale.

In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.