Fluke 1587 FC Insulation Multimeter

The high-performance 2-in-1 insulation DMM

The s combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

  • The adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:
  • PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

Discover the Fluke 1587 FC Insulation Multimeter at Mektronics Australia – your trusted source for quality tools and equipment!

  • PI/DAR timed ratio tests
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test (1587 FC: 0.01 MΩ to 2 GΩ)
  • Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V) for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Large display with backlight
  • Rugged, utility hard case allows you to bring everything you need for the job
  • Included accessories: Remote probe, test leads and probes, alligator clips, K-type thermocouple
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient hands free operation
  • Three-year standard warranty; extendable to five-years through product registration within 45 days of purchase
 Includes
  • Remote probe
  • Test leads
  • Alligator clips
  • K-type thermocouple
  • Hard case
  • User documentation

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage 
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance  10 MΩ (nominal), <100 pF
Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio  >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA 
Resolution 0.01 mA 
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
Overload protection  1000 V rms or dc
Open circuit test voltage  <8.0 V dc
Short circuit current  <1.1 mA
¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz  0.01 Hz  ±(0.1% + 1)
999.9 Hz  0.1 Hz  ±(0.1% + 1)
9.999 kHz  0.001 kHz  ±(0.1% + 1)
99.99 kHz  0.01 kHz  ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 mV 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV 
DC Trigger Levels¹ to 20 kHz² NA
6.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  1.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V 
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  10.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V 
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  300.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input
Capacitance
Range  Resolution  Accuracy ±(% of Rdg+Counts)
1000 nF  1 nF ±(1.2% + 2)
10.00 μF  0.01 μF ±(1.2% + 2)
100.0 μF  0.1 μF ±(1.2% ±90 counts)
9999 μF  1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range  Resolution  Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C  0.1 °C  ±(1% + 10 counts)
-40 ° F to 998 ° F  0.1 °F  ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Measurement range 0.01 MΩ to 2 GΩ
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 μF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 μF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ 
Resolution 100 MΩ 
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic Compatibility 
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating)
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries  Four AA batteries (NEDA 15A or IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

1587 FC Insulation Multimeter Data Sheet

SHIPPING

A delivery and handling charge applies to all orders with the exception of back-ordered items.

Unless otherwise required by Buyer, Seller will make transport arrangements as follows:

For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods

For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.

Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.

Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.

DELIVERY TIME

All quoted delivery or consignment dates are estimates only, given without engagement.

Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.

Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer

a) in the event of a delay in consignment or delivery of goods: or

b) in the event of non delivery.

Goods offered ex-stock by Seller are subject to prior sale.

In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.