The BenchVent BV930H-D is a large ducted hood mounted local extraction cabinet designed specifically for laboratories. It is commonly used in dental & medical labs, pharmaceutical laboratories, research & development and school science laboratories.
This unit exhaust air through a flexi-duct externally to the atmosphere. Although, it’s a ducted fume extractor, you don’t need to have a special vent to use the BV930H-D. Its flexi-ducts can be fitted to a normal domestic vent or placed on a partially opened window. (We would recommend either one hole per duct or, if combining into on outlet, the outlet should be 150mm diameter)
The BV930H-D also provides operators with a safe workstation, as handling of all the potential harmful chemicals is done within the hood enclosure in front of the the intake filter area. For artwork applications, the enclosure can accommodate a standard A1 drawing boards, which will fit at an angle so the unit captures the over-spray efficiently, keeping the surrounding working area clean.
The BV930H-D fume cabinet is designed for immediate operator protection . If outside venting isn’t possible, BenchVent also offers re-circulatory fume cabinets such as the BV660H-C and BV930H-C. Both units have higher filtration specifications.
Download the datasheet for more information: BV930H-D Datasheet
** ADDITIONAL CHARGES MAY APPLY FOR AIR FREIGHT & BULKY ITEMS **
Discover the BenchVent Hood Mounted Ducted Fume Cabinet (Hood ID 960 x 660 x 620) BV930H-D at Mektronics Australia – your trusted source for quality tools and equipment!
The BV930H-D is suitable to filter fumes, vapours and particulates from:
Spray Adhesives
Conformal coatings (thin polymer film usually used to coat circuit boards)
Paints
Monomers
Resin
Sealants
Solders
Light Grinding
Organic Solvents
Cleaners
Hazardous powders & particulates
Filter unit with 2 x centrifugal fans
Hood Enclosure
Hood Light
Polycarbonate hinged front panel
2 x 2mtrs flexi-duct – 100mm diameter
Particulate filter
Power Lead
Data/Warranty Booklet
All BenchVent filtration and extraction systems carry a lifetime guarantee.
The particulate (intake) filter is a three stage graduated fibre filter with a high 'dust' holding capacity for long life. Filtration to 5 micron particles. NB: Spray particulate sizes vary from 10 to 20 microns. The dual process of filtration and then extraction to atmosphere via flexi-duct, vastly reduces and/or eliminates operator exposures to potentially hazardous substances.
Weight |
125 kg |
---|---|
Dimensions |
960 x 660 x 620 (wxhxd) [internal] 960 x 740 x 720 (wxhxd) [overall] |
Description |
Steel construction finished in grey – fan/filter unit mounted onto hood enclosure complete with clear polycarbonate panel and hood lighting – particulate filter – 2 x centrifugal blowers, external rotor motor type, brushless, UL, VDE and CSA approved – sealed electrical wiring and switch, downstream of filter. Flexi-ducts; 2 metres x 100mm dia. |
Air Volume at Free Air |
710 m3/hr |
Ave. Air Velocity at Filter Face |
0.60 m/sec |
Ave. Air Velocity at Hood Face |
0.55 m/sec |
Filters |
Standard Particle Filter – IFA2P |
Noise Level LAeq dB(A) |
60 db(A) |
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.