Amprobe AMP-220 600A AC/DC TRMS Clamp Meter
Amprobe AMP-220 600A AC/DC TRMS Clamp Meter
Amprobe AMP-220 600A AC/DC TRMS Clamp Meter
Amprobe AMP-220 600A AC/DC TRMS Clamp Meter
Image for Illustrative Purposes Only
Fluke Logo

Amprobe AMP-220 600A AC/DC TRMS Clamp Meter

SKU: FLUAMP-220

AMP-220

$426.00

EX. GST
$468.60
INC GST
Out of Stock: Available to Order

own it from $10 a week with Group 2 Copy Created with Sketch.

DESCRIPTION
Features
Inclusions
Specifications
Shipping & Delivery

Amprobe AMP-220 600A AC/DC TRMS Clamp Meter

With a full range of AC/DC current, AC/DC voltage, and frequency measurement functions for basic electrical troubleshooting, the AMP-220 clamp meter with its large backlit display is an excellent amp clamp meter choice. Rated CAT III 600 V, the AMP-210 clamp meter offers True-RMS sensing, fast response processor, non-contact voltage detection, capacitance, resistance and continuity measurements to enhance efficiency and safety in today's complex electrical environments. The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, enabling accurate current measurement of both large and small diameter wires. A low pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency).

Discover the Amprobe AMP-220 600A AC/DC TRMS Clamp Meter at Mektronics Australia – your trusted source for quality tools and equipment!

  • Measures AC/DC Current to 600 A and AC/DC Voltage to 600 V

  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments

  • Amp-Tip delivers precise low AC current measurements "“ 0 to 60 A

  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives

  • Capacitance measurement, continuity beeper and diode test

  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils

  • Offers data hold and relative zero for quick analysis

  • Maximizes battery life with auto power off and low battery indicator

  • Backlit display for easy measurement viewing in bright and dim environments

  • Accommodates conductors up to 1.37 in (35 mm)

  • CAT III 600 V safety rated

  • AMP-220

  • Test Leads

  • (2) AAA Batteries (installed)

  • Carrying Case

FEATURE

AMP-210

AMP-220

AMP-310

AMP-320

AMP-330

AC voltage (True-rms)

Range:

0 to 600.0 V

0 to 1000.0 V

Accuracy:

±1.0% + 5LSD (50 to 60 Hz)

±0.8% + 5LSD (50 to 60 Hz)

DC voltage

Range:

0 to 600.0 V

Accuracy:

±1.0% + 5LSD

AC+DC voltage

Range:

"“

0 to 600.0 V

"“

0 to 600.0 V

0 to 1000.0 V

Accuracy:

"“

±1.2% + 7LSD (50 to 60 Hz)

"“

±1.2% + 7LSD (50 to 60 Hz)

±1.0% + 7LSD (50 to 60 Hz)

±1.8% + 7LSD (DC 40 to 200 Hz)

±1.2% + 7LSD 200 to 400 Hz)

AC current

Range:

0 to 600.0 A

Accuracy:

±1.8% + 5LSD (50 to 60 Hz)

±2.0% + 5LSD (100 to 400 Hz)

DC current

Range:

"“

0 to 600.0 A

"“

0 to 600.0 A

0 to 1000.0 A

Accuracy:

"“

±2.0% + 5LSD (DC 50 to 100 Hz)

"“

±2.0% + 5LSD (DC 50 to 100 Hz)

±1.8% + 5LSD (DC 50 to 100 Hz)

AC+DC current

Range:

"“

0 to 600.0 A

"“

0 to 600.0 A

0 to 1000.0 A

Accuracy:

"“

±2.2% + 7LSD (DC 50 to 100 Hz)

±2.7% + 7LSD (100 to 400 Hz)

"“

±2.2% + 7LSD (DC 50 to 100 Hz)

±2.7% + 7LSD (100 to 400 Hz)

±2.2% + 7LSD (40 to 100 Hz)

±2.5% + 7LSD (100 to 400 Hz)

Precise low current AC

Range:

0 to 60.00 A

Accuracy:

±1.5% + 5LSD (50 to 60 Hz)

±1.5% + 5LSD (50 to 60 Hz)

±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz)

±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz)

±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz)

Precise low current DC

Range:

"“

0 to 60.0 A

"“

0 to 60.0 A

0 to 60.00 A

Accuracy:

"“

±2.0% + 5LSD

"“

±2.0% + 5LSD

±1.5% + 5LSD (0.00 to 20.00 A)

±3.0% + 5LSD (>20.00 to 60.00 A)

Micro amps

Range:

"“

"“

0 to 2000 µA

Accuracy:

"“

"“

±1.0% + 5LSD

Frequency

Range:

5.00 to 999.9 Hz

Accuracy:

±1.0% + 5LSD (600 V range)

Range:

50.0 to 400.0 Hz

Accuracy:

±2.0% + 4LSD (600 A range)

Resistance

Range:

0.0 to 60.00 kΩ

Accuracy:

±1.0% + 5LSD

Capacitance

Range:

0.0 to 2500 µF

Accuracy:

±2.0% + 4LSD

Continuity beeper

ON ≤ 10 Ω

Off > 250 Ω

Temperature*

(Type K thermocouple)

"“

"“

-40.0 to 752 °F

-40.0 to 400 °C

"“

"“

±1.0% + 3.0 °F (-40.0 to 14.0 °F)

±1.0% + 1.5 °F (>40.0 to 99.9 °F)

±1.0% + 2.0 °F (100 to 752 °F)

±1.0% + 1.5 °C (-40.0 to 10.0 °C)

±1.0% + 0.8 °C (>-10.0 to 99.9 °C)

±1.0% + 1.0 °C (100 to 400 °C)

Non-contact voltage

10 V to 1000 V AC (50 to 60 Hz)

Phase rotation indication

"“

"“

Rotation-R for main supply

Rotation-M for motors

Diode test

Jaw opening

1.18 in (30 mm)

1.37 in (35 mm)

1.18 in (30 mm)

1.37 in (35 mm)

2.0 in (51 mm)

Safty rating

CAT III 600 V

CAT IV 600V

CAT III 1000 V

Special Features

In-rush current

"“

Peak hold (Crest)

"“

"“

"“

"“

Relative zero

Max/Min/Avg

Data hold

Backlight

Auto power off

Work light

"“

"“

"“

"“

*Error does not include Type-K thermocouple errors


SHIPPING

A delivery and handling charge applies to all orders with the exception of back-ordered items.

Unless otherwise required by Buyer, Seller will make transport arrangements as follows:

For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods

For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.

Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.

Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.

DELIVERY TIME

All quoted delivery or consignment dates are estimates only, given without engagement.

Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.

Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer

a) in the event of a delay in consignment or delivery of goods: or

b) in the event of non delivery.

Goods offered ex-stock by Seller are subject to prior sale.

In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.