For the temperature calibration professional that wants a highly accurate, easy-to-use, single function thermocouple temperature calibrator the is the ideal test tool.
Discover the Fluke 714B Thermocouple Calibrator at Mektronics Australia – your trusted source for quality tools and equipment!
- The 714B can measure and simulate (17) different thermocouple types and millivolts
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Hanging tool designed in and included with every unit
- Configurable 0% and 100% source settings for quick 25% linearity checks
- Linear ramp and 25% step auto ramp based on 0% and 100% settings
- Dual inputs and backlit display for easy interpretation of measurements
- Power down settings remembered at power up for easy restart of tests
- 1-year and 2-year specifications and traceable certificate of calibration
- Magnetic hanging tool
- Batteries
- Manual
- Traceable calibration certificate
- Test leads
General Specifications | |||||
Maximum voltage applied between any terminal and earth ground or between any two terminals | 30 V | ||||
Operating temperature | -10°C to 50°C | ||||
Storage temperature | -30°C to 60°C | ||||
Operating altitude | 2,000 m | ||||
Storage altitude | 12,000 m | ||||
Relative humidity (% RH operating without condensation) | Non condensing 90% (10°C to 30°C) 75% (30°C to 40°C) 45% (40°C to 50°C) (Without condensation) |
||||
Vibration requirements | MIL-T-28800E, Class 2 | ||||
Drop text requirements | 1 m | ||||
IP Rating | IEC 60529: IP52 | ||||
Electromagnetic environment | IEC 61326-1, Portable | ||||
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 | ||||
Power supply | 4 AA NEDA 1.5A IEC LR6 batteries | ||||
Size (H x W x L) | 52.5 x 84 x 188.5 mm | ||||
Weight | 515 g | ||||
DC mA Measurement | |||||
Resolution | Range | Accuracy (% of reading + counts) | |||
0-24 mA | 0.001 mA | 0.010% + 2 μA | |||
Temperature coefficient | ±(0.002% of reading + 0.002% of range) /°C (< 18°C or > 28°C) | ||||
Millivolt Measurement and Source | |||||
Resolution | Range | Accuracy (% of reading +counts) | |||
-10 mV to 75 mV | 0.01 mV | 0.015% + 10 μA | |||
Temperature coefficient | ±(0.002% of reading + 0.002% of range) /°C (< 18°C or > 28°C) | ||||
Thermocouple Input and Output | |||||
TC Type | Range (°C) | Measure (°C) | Source (°C) | ||
1 year | 2 year | 1 year | 2 year | ||
E | -250 to 200°C | 1.3 | 2.0 | 0.6 | 0.9 |
-200 to -100°C | 0.5 | 0.8 | 0.3 | 0.4 | |
-100 to 600°C | 0.3 | 0.4 | 0.3 | 0.4 | |
600 to 1000°C | 0.4 | 0.6 | 0.2 | 0.3 | |
N | -200 to -100°C | 1.0 | 1.5 | 0.6 | 0.9 |
-100 to 900°C | 0.5 | 0.8 | 0.5 | 0.8 | |
900 to 1300°C | 0.6 | 0.9 | 0.3 | 0.4 | |
J | -210 to -100°C | 0.6 | 0.9 | 0.3 | 0.4 |
-100 to 800°C | 0.3 | 0.4 | 0.2 | 0.3 | |
800 to 1200°C | 0.5 | 0.8 | 0.3 | 0.3 | |
K | -200 to -100°C | 0.7 | 1.0 | 0.4 | 0.6 |
-100 to 400°C | 0.3 | 0.4 | 0.3 | 0.4 | |
400 to 1200°C | 0.5 | 0.8 | 0.3 | 0.4 | |
1200 to 1372°C | 0.7 | 1.0 | 0.3 | 0.4 | |
T | -250 to -200°C | 1.7 | 2.5 | 0.9 | 1.4 |
-200 to 0°C | 0.6 | 0.9 | 0.4 | 0.6 | |
0 to 400°C | 0.3 | 0.4 | 0.3 | 0.4 | |
B | 600 to 800°C | 1.3 | 2.0 | 1.0 | 1.5 |
800 to 1000°C | 1.0 | 1.5 | 0.8 | 1.2 | |
1000 to 1820°C | 0.9 | 1.3 | 0.8 | 1.2 | |
R | -20 to 0°C | 2.3 | 2.8 | 1.2 | 1.8 |
0 to 100°C | 1.5 | 2.2 | 1.1 | 1.7 | |
100 to 1767°C | 1.0 | 1.5 | 0.9 | 1.4 | |
S | -20 to 0°C | 2.3 | 2.8 | 1.2 | 1.8 |
0 to 200°C | 1.5 | 2.1 | 1.1 | 1.7 | |
200 to 1400°C | 0.9 | 1.4 | 0.9 | 1.4 | |
1400 to 1767°C | 1.1 | 1.7 | 1.0 | 1.5 | |
C | 0 to 800°C | 0.6 | 0.9 | 0.6 | 0.9 |
800 to 1200°C | 0.8 | 1.2 | 0.7 | 1.0 | |
1200 to 1800°C | 1.1 | 1.6 | 0.9 | 1.4 | |
1800 to 2316°C | 2.0 | 3.0 | 1.3 | 2.0 | |
L | -200 to -100°C | 0.6 | 0.9 | 0.3 | 0.4 |
-100 to 800°C | 0.3 | 0.4 | 0.2 | 0.3 | |
800 to 900°C | 0.5 | 0.8 | 0.2 | 0.3 | |
U | -200 to 0°C | 0.6 | 0.9 | 0.4 | 0.6 |
0 to 600°C | 0.3 | 0.4 | 0.3 | 0.4 | |
BP | 0 to 1000°C | 1.0 | 1.5 | 0.4 | 0.6 |
1000 to 2000°C | 1.6 | 2.4 | 0.6 | 0.9 | |
2000 to 2500°C | 2.0 | 3.0 | 0.8 | 1.2 | |
XK | -200 to 300°C | 0.2 | 0.3 | 0.2 | 0.5 |
300 to 800°C | 0.4 | 0.6 | 0.3 | 0.6 | |
G | 100 to 300°C | 1.6 | 2.4 | 1.2 | 1.8 |
300 to 1500°C | 1.0 | 1.5 | 1.0 | 1.5 | |
1500 to 2320°C | 2.0 | 3.0 | 1.6 | 2.4 | |
D | 0 to 300°C | 1.6 | 2.4 | 1.2 | 1.8 |
300 to 1500°C | 1.0 | 1.5 | 1.0 | 1.5 | |
1500 to 2315°C | 2.0 | 3.0 | 1.6 | 2.4 | |
P | 0 to 1000°C | 1.6 | 2.4 | 0.6 | 0.9 |
1000 to 1395°C | 2.0 | 3.0 | 0.8 | 1.2 | |
M | -50 to 100°C | 1.0 | 1.5 | 0.4 | 0.6 |
100 to 1000°C | 1.6 | 2.4 | 0.6 | 0.9 | |
1000 to 1410°C | 2.0 | 3.0 | 0.8 | 1.2 |
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.