Image for Illustrative Purposes Only
Fluke 110 Electrical TRMS Multimeter for APAC
SKU: FLU110/APAC
FLUKE-110/APAC
DESCRIPTION
Features
Includes
Specifications
Shipping & Delivery
Fluke 110 Electrical TRMS Multimeter for APAC
Compact true-rms meter for accurate electrical installation and troubleshooting
The Fluke 110 is a versatile multimeter for electrical measurements and troubleshooting. Trusted by residential and commercial electricians for troubleshooting and maintenance. The 110 is for professional use, where true-rms accuracy is needed.
Discover the Fluke 110 Electrical TRMS Multimeter for APAC at Mektronics Australia – your trusted source for quality tools and equipment!
-
True-rms ac voltage for accurate measurements on non-linear signals
-
Large white LED backlight to work in poorly lit areas
-
Resistance and continuity
-
Min/Max/Average to record signal fluctuations
-
CAT III 600 V safety rated
-
Fluke 110 True-RMS Multimeter
-
TL75 Hard Point™ Test Lead Set with protective caps
-
9 V battery (installed)
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )
General specifications | |
---|---|
Maximum voltage (between any terminal and earth ground) | 600V |
Safety | IEC 61010-1, Pollution degree 2 IEC 61010-2-033, CAT III 600 V |
Display | Digital: 6,000 counts, updates 4/sec |
Bar graph | 33 segments, updates 32/sec |
Temperature Operating Storage |
-10 °C to + 50 °C -40 °C to + 60 °C |
Battery |
9 volt Alkaline, IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Accuracy |
|||
---|---|---|---|
Measurement |
Range |
Resolution |
Accuracy ± ([% of reading] + [counts]) |
DC millivolts |
600.0 mV |
0.1 mV |
0.5 % + 2 |
DC volts |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 2 |
Accuracy |
|||
---|---|---|---|
Measurement |
Range |
Resolution |
Accuracy ± ([% of reading] + [counts]) |
AC millivolts1 true-rms |
600.0 mV |
0.1 mV |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
600 Ω |
1 Ω |
Beeper on < 20 Ω, off> 250 Ω; detects opens or shorts of 500 μs or longer. |
Ohms |
600.0 Ω |
0.1 Ω |
0.9 % + 2 |
6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ |
0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ |
0.9 % + 1 |
|
40.00 MΩ |
0.01 MΩ |
5 % + 2 |
1All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled.
SHIPPING
A delivery and handling charge applies to all orders with the exception of back-ordered items.
Unless otherwise required by Buyer, Seller will make transport arrangements as follows:
For deliveries within the metropolitan areas of mainland State capital cities a standard freight charge may be added to invoice; goods
For delivery outside those areas, seller will select the transport to be used and prepay freight for Buyer. Seller will then bill Buyer for freight at Seller's discretion.
Should the Buyer request goods be sent to a Post Office box the Buyer acknowledges this method is the only available and therefore the Seller is not liable for undelivered goods.
Free shipping on orders over $199 incl GST (valid for 1 delivery per order and excludes NT, WA & TAS). If only part of the order is in stock, the customer has the option of paying for a second delivery if they require a partial shipment prior to all goods becoming available. Mektronics Australia reserves the right to charge additional freight in the event of hazardous, bulky or heavy items ordered.
DELIVERY TIME
All quoted delivery or consignment dates are estimates only, given without engagement.
Delay in consignment of any part of an order shall not relieve Buyer of its obligation to accept and pay for the remainder of the order.
Except as provided in paragraph 1.2 of Terms & Conditions, seller will not be liable to pay damages or compensation for any injury or loss sustained by Buyer
a) in the event of a delay in consignment or delivery of goods: or
b) in the event of non delivery.
Goods offered ex-stock by Seller are subject to prior sale.
In the event of any happening beyond Seller's reasonable control in consequence of which Seller cannot effect consignment by the time or times quoted or specified, Seller shall be entitled to consign part only of an order, suspend consignment or extend the time for consignment, for the period during which such cause of delay operates, or may cancel the order, and in the event of such suspension, extension or cancellation, Seller shall not be liable for damages.