{"product_id":"rohde-schwarz-scope-rider-4-channel-500-mhz","title":"Rohde \u0026 Schwarz Scope Rider, 4 Channel, 500 MHz","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eWhen debugging embedded devices in the lab or analyzing complex problems in the field, the Rohde \u0026amp; Schwarz Scope Rider offers the performance and capabilities of a lab oscilloscope as well as the form factor and ruggedness of a battery-operated handheld device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRohde \u0026amp; Schwarz Scope Rider Key Facts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-156160.5\"\u003e\n\u003cul\u003e\n\u003cli\u003e60 MHz to 500 MHz with 5 Gsample\/s sampling rate\u003c\/li\u003e\n\u003cli\u003eIsolated channels with CAT IV 600 V \/ CAT III 1000 V rating\u003c\/li\u003e\n\u003cli\u003e10-bit ADC\u003c\/li\u003e\n\u003cli\u003e50 000 waveforms per second\u003c\/li\u003e\n\u003cli\u003eCapacitive touch and keypad operation\u003c\/li\u003e\n\u003cli\u003e5 in 1: Lab performance oscilloscope, logic analyzer, protocol analyzer, data logger and digital multimeter\u003c\/li\u003e\n\u003cli\u003eIP51 housing meeting military environmental requirements\u003c\/li\u003e\n\u003cli\u003eWireless LAN and Ethernet for web-based remote control and quick data access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp id=\"ti_expandedbox_c_t-156160.7\"\u003e\u003cstrong\u003eSuperior performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eLab performance in a rugged and portable design\u003c\/li\u003e\n\u003cli\u003eSafe measurements on power electronics\u003c\/li\u003e\n\u003cli\u003eHigh-speed acquisition system with deep history: never miss rare faults again\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e5 instruments in one handheld package\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv id=\"ti_expandedbox_c_t-156160.7\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eLab performance oscilloscope\u003c\/li\u003e\n\u003cli\u003eLogic analyzer\u003c\/li\u003e\n\u003cli\u003eProtocol analyzer\u003c\/li\u003e\n\u003cli\u003eData logger\u003c\/li\u003e\n\u003cli\u003eDigital multimeter (Additional multimeter channel in two-channel model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCapacitive touch and keypad operation\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eFull operation via touch panel or keypad\u003c\/li\u003e\n\u003cli\u003eSee more with a 7“ color display\u003c\/li\u003e\n\u003cli\u003eEasy parameter adjustment with multifunction wheel\u003c\/li\u003e\n\u003cli\u003eLarge buttons for use with gloves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eOutstanding protection\u003c\/strong\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum safety in all environments: CAT IV 600 V \/ CAT II 1000 V\u003c\/li\u003e\n\u003cli\u003eHighest sensitivity and safe high-voltage measurements at the same time\u003c\/li\u003e\n\u003cli\u003eIP51 housing – tested in line with military environmental standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cstrong\u003eExcellent connectivity and much more\u003c\/strong\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eWireless LAN and Ethernet for web-based remote control and quick data access\u003c\/li\u003e\n\u003cli\u003eFinish faster with one-touch documentation\u003c\/li\u003e\n\u003cli\u003eMicroSD card and USB device\/host support\u003c\/li\u003e\n\u003cli\u003eMore than 4 hours of battery power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eVertical System\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput channels\u003c\/td\u003e\n\u003ctd\u003e2-channel models\u003c\/td\u003e\n\u003ctd\u003e2 oscilloscope channels, 1 digital multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4-channel models\u003c\/td\u003e\n\u003ctd\u003e4 oscilloscope channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd\u003eBNC inputs\u003c\/td\u003e\n\u003ctd\u003eCAT IV 300 V (RMS), 424 V (Vp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ewith probe R\u0026amp;S®RT-ZI10 or R\u0026amp;S®RT-ZI11\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e+\/-200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAcquisition and Horizontal System\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum realtime sampling rate\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2 \/ 4 channels active\u003c\/td\u003e\n\u003ctd\u003e5 \/ 2.5 \/ 1.25 Gsample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition memory\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2 \/ 4 channels active\u003c\/td\u003e\n\u003ctd\u003e500 \/ 250 \/ 125 ksample \/ channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRealtime waveform acquisition rate\u003c\/td\u003e\n\u003ctd\u003emax.\u003c\/td\u003e\n\u003ctd\u003e50 000 waveforms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimebase range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ns\/div to 500 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLogic Analyzer (MSO) functionality (optional: R\u0026amp;S®RTH-B1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput channels \/ memory depth\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e8 logic channels \/ 125 kSample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth \/ sampling rate\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e250 MHz \/ 1.25 GSample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDigital Trigger System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger modes\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eauto, normal, single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger types\u003c\/td\u003e\n\u003ctd\u003e Advanced trigger types optional (R\u0026amp;S®RTH-K19)\u003c\/td\u003e\n\u003ctd\u003e14 trigger types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAutomatic oscilloscope measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic measurements\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e33 measurement functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMask testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMask definition\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTolerance tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActions on violation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003enone, beep, stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eProtocol Trigger \u0026amp; Decode\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003e(Optional: R\u0026amp;S®RTH-K1, R\u0026amp;S®RTH-K2)\u003c\/td\u003e\n\u003ctd\u003eI2C, SPI, UART\/RS-232\/RS-422\/RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eData logger\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of simult. logging channels\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement speed\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1\/2\/5 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory depth\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e2 Msample per logging channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eDigital voltmeter \/ Digital Multimeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e2-channel version (Digital Multimeter)\u003c\/td\u003e\n\u003ctd\u003e10 000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4-channel version (Digital voltmeter)\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage and current\u003c\/td\u003e\n\u003ctd\u003eCurrent with optional current probe or shunt\u003c\/td\u003e\n\u003ctd\u003eDC, AC, AC+DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWith PT100 temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance, continuity, diode test,\u003cbr\u003ecapacity, frequency\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOnly 2-channel version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eW x H x D\u003c\/td\u003e\n\u003ctd\u003e201 mm x 293 mm x 74 mm (7.91 in x 11.54 in x 2.91 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ewith battery\u003c\/td\u003e\n\u003ctd\u003e2.4 kg (5.3 lb) (nom.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIP51, in line with IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e7.0\" LC TFT 800 x 480 color display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUSB host, USB device, LAN, Wireless LAN (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Rohde \u0026 Schwarz","offers":[{"title":"Default Title","offer_id":41045581070492,"sku":"RSRTH1054","price":9889.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/rsrth1002_1_1_1_1_1_1_1_1_1.jpg?v=1633643995","url":"https:\/\/mektronics.com.au\/products\/rohde-schwarz-scope-rider-4-channel-500-mhz","provider":"Mektronics Australia","version":"1.0","type":"link"}