{"product_id":"prostat-pas-853brm-digital-surface-resistance-test-kit","title":"Prostat PAS-853BRM Digital Surface Resistance Test Kit","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSurface Resistance Kit from 0.01 ohm to 9.99x10\u003csup\u003e12\u003c\/sup\u003e ohms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal Full Range Tolerance Averages \n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully Automatic Resistance Range, Test Voltage and Electrification Period control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetermines if a surface is Dissipative, Conductive, or Insulative\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures resistance point-to-point(Rtt) and point-to-ground (Rtg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures resistance of Static Control Floors, ESD Work Surfaces and Packaging Material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConforms to all ESD Association Standards for Resistive Characterization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes 2 each Conductive Rubber Electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaged in a hard shell Carrying Case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertificate of Calibration Traceable to NIST included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e Specifications\u003c\/strong\u003e\n\u003cp class=\"dl1c\"\u003eCONTROLS\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eON\/OFF Battery Bus Cut-off\u003c\/span\u003e\u003cbr\u003eSlide Switch ON SIDE OF CASE\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eON\u003c\/span\u003e: Energizes instrument and LCD displays Software Version then GO A with AUTO indication (Default)\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eOFF\u003c\/span\u003e: Isolates battery and DC voltage from instrument controls and circuit. Use for transport and storage\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eTEST Pad\u003c\/span\u003e\u003cbr\u003eWith Test Leads installed: Press once \u0026amp; Release.\u003cbr\u003eMeasurements performed automatically\u003c\/p\u003e\n\u003cp\u003eIn conjunction with MODE changes from Auto operation to Continuous\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eMODE Pad\u003c\/span\u003e\u003cbr\u003eSteps through Auto\/Voltage ranges with each press of MODE Pad:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAUTO: Default automatic resistance range \u0026amp; Voltage control\u003c\/li\u003e\n\u003cli\u003e\u0026lt;10V: Manual Operation 0.01 to =10V Test Voltage;\n\u003cul\u003e\n\u003cli\u003eResistance Range: 0.01E-1 to 9.99E9 O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e10V: Manual Operation at 10V (Nominal, Semi-Constant)\n\u003cul\u003e\n\u003cli\u003eResistance Range: 0.98E4 to 9.99E10 O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e100V: Manual Operation at 100V (±\u0026lt;5V) Constant Voltage\n\u003cul\u003e\n\u003cli\u003eResistance Range: 0.98E6 to 9.99E12 O\u003c\/li\u003e\n\u003cli\u003eWhen data in HOLD, press MODE to terminate HOLD without changing operational mode\u003c\/li\u003e\n\u003cli\u003ePress MODE with TEST to change from Auto to Continuous\u003c\/li\u003e\n\u003cli\u003eUsed to measure lead resistance (NULL)\u003c\/li\u003e\n\u003cli\u003eUsed by Prostat Authorized Technicians for Voltage Calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp class=\"dl1c\"\u003eCONNECTIONS\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePositive (+)\u003c\/span\u003e: Test Voltage (RED) – Supplies test voltage to electrodes\/fixtures\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNegative (-)\u003c\/span\u003e: Current sensing (BLACK) – Conducts current from electrode, fixtures or Ground to instrument\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChassis\u003c\/span\u003e: Shielding connection to chassis (WHITE) – Reduces transmitted energy and effect on current measurement\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNote\u003c\/span\u003e: ¾ inch spacing between RED and BLACK accommodates dual banana BNC adapters\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"dl1c\"\u003eINDICATION\u003c\/p\u003e\n\u003cp\u003eColored LED’s indicate instrument operational \u003cspan\u003eMODE\u003c\/span\u003e and Test Voltage (\u003cspan\u003eYELLOW\u003c\/span\u003e) used for the current measurement, as well as measurement completion (\u003cspan\u003eGREEN LED\u003c\/span\u003e).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAUTO: ON during automatic operations; OFF in Manual mode\u003c\/li\u003e\n\u003cli\u003e\u0026lt;10V\u003c\/li\u003e\n\u003cli\u003e10V\u003c\/li\u003e\n\u003cli\u003e100V\u003c\/li\u003e\n\u003cli\u003eGREEN LED: Measurement hold\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"dl1c\"\u003eTYPICAL TOLERANCES\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003eNominal performance by range:\u003c\/p\u003e\n\u003cp\u003e0.01E- 1 – 1.0E 0 O 1.0E 0 – 9.99E10 O 1.0E11 – 9.99E12 O \n\u003c\/p\u003e\u003cp class=\"dl1c\"\u003eTEST VOLTAGES\u003c\/p\u003e\n\u003cp\u003eAutomatically selected and controlled in \u003cspan\u003eAUTO\u003c\/span\u003e mode. May be manually selected by pressing \u003cspan\u003eMODE\u003c\/span\u003e pad in the following order:\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u0026lt;10V Variable based on resistance load:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 0.001 to =10V\u003c\/li\u003e\n\u003cli\u003eFunctional in AUTO within range 0.01 O - \u0026lt;1.0E+4 O\u003c\/li\u003e\n\u003cli\u003eManual Operation Resistance Range: 0.01E-1 to 9.99E+9 O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e10V Constant Voltage (Under Load):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest Voltage Varies ± \u0026lt;5% in AUTO or Manual Operations\u003c\/li\u003e\n\u003cli\u003eFunctional in AUTO within range 1.0E+4O - \u0026lt;1.0E+6 O\u003c\/li\u003e\n\u003cli\u003eManual Operation Resistance Range: 0.9E+4 to 9.99E+10 O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e100V Constant Voltage (Under Load):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest Voltage Varies ± \u0026lt;2% in AUTO or Manual Operations\u003c\/li\u003e\n\u003cli\u003eFunctional in AUTO within range 1.0E+6 O - \u0026lt;1.0E+13 O\u003c\/li\u003e\n\u003cli\u003eManual Operation Resistance Range: 0.90E6 to 9.99E12 O\u003cbr\u003eReturns to Auto Mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"dl1c\"\u003eMODES OF OPERATIONS\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGO A: \u003c\/span\u003ePerforms all automatic and manual voltage select functions, stops and displays measurements after Electrification Period (EP) is complete, then displays data with Green LED ON for 10 seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGO C:\u003c\/span\u003e Performs all automatic and manual voltage select functions, continuously displays measurements until the operator presses \u003cspan\u003eMODE\u003c\/span\u003e or \u003cspan\u003eTEST\u003c\/span\u003e pads. \u003cspan\u003eGO C\u003c\/span\u003edisables electrification period controls.\u003c\/p\u003e\n\u003cp class=\"dl1c\"\u003ePOWER: One 9V alkaline transistor battery; battery life \u0026gt; 50 hours\u003c\/p\u003e\n\u003cp class=\"dl1c\"\u003eDIMENSIONS: 7.25 in. (184 mm) x 4.3 in, (109 mm) x 1.4 in.\u003c\/p\u003e\n\u003cp class=\"dl1c\"\u003eWEIGHT: 13.2 oz. (375 gram) with battery installed\u003c\/p\u003e\n\u003cp class=\"dl1c\"\u003eNOTES: 1Tolerance and accuracy measurements were conducted under controlled conditions with close tolerance reference resistors.\u003c\/p\u003e\n\u003cp\u003eDo not attempt to open instrument case:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo internal operational parts or adjustments\u003c\/li\u003e\n\u003cli\u003eProvides access to 100DCV power supply\u003c\/li\u003e\n\u003cli\u003eDamage to instrument and environmental seals may occur\u003c\/li\u003e\n\u003cli\u003eWill void warranty\u003c\/li\u003e\n\u003cli\u003eStore instrument in case and dry environment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul class=\"detailbullets\"\u003e\n\u003cli\u003e\n\u003cp\u003ePAS-853B Wide Range Ohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePAS-853BLR 200 cm Silicone Test Lead - Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePAS-853BLB 200 cm Silicone Test Lead - Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePTB-915 Audit Test Bed \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePSI-870MAC Alligator Clip (2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePRS-801BC Bulldog Clip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePAS-853S Test Lead Shunt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePRS-801-W 5 lbs Conductive Rubber Electrodes (2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePAS-105C Carrying Case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertificate of Calibration Traceable to NIST\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Prostat","offers":[{"title":"Default Title","offer_id":41045566718108,"sku":"PROPAS-853BRM","price":4453.13,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/propas-853brm.jpg?v=1633643675","url":"https:\/\/mektronics.com.au\/products\/prostat-pas-853brm-digital-surface-resistance-test-kit","provider":"Mektronics Australia","version":"1.0","type":"link"}