{"product_id":"fluke-t6-1000-prv240fs-electrical-tester-with-fieldsense-technology-1000v-ac-proving-unit","title":"Fluke T6-1000\/PRV240FS Electrical Tester with FieldSense Technology, 1000V AC \u0026 Proving Unit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp class=\"short-description mhide ipad-view-setting\"\u003eThe kit includes the T6-1000 Electrical Tester with FieldSense technology and the PRV240FS Proving unit. Measure voltage the same way you would measure current, without test lead contact to live voltage. Much more than just a voltage detector, giving you reliable voltage and current measurement, without test leads, and without contacting a bare, metal conductor. The proving kit provides a safe method to verify that your electrical test tool is operating properly before you conduct any live tests.\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eT6 Electrical Testers let you test where it used to be impossible by measuring voltage and current through the open jaw. You can measure voltage (not just detect voltage) without making metallic contact with a live conductor. This means you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure voltage and current simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure in tight spaces by not needing to use test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSave time by taking measurements without needing to remove covers and wire nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMake measurements with one hand, reducing risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasy to read display with backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable Slim Reach probe tips are customized for national electrical standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest leads accept Fluke accessory test clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTPAK Compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial electricans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLight industrial electricians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBasic troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of voltage and contunuity values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRapidly checking voltage and current measurements without test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of individual circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe front-line, go-to tool that fits in pocket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eReduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification (PPE is still needed for absence of voltage testing when appropriate).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSources both ac and dc steady-state voltage - supplies 240 V dc\/ac\u003c\/li\u003e\n\u003cli\u003eA single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool\u003c\/li\u003e\n\u003cli\u003eCompatible with both high impedance or low impedance multimeters, clamp meters or two pole testers\u003c\/li\u003e\n\u003cli\u003eVoltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact\u003c\/li\u003e\n\u003cli\u003eLong battery life - 5,000 tests per set of four AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFluke T6-1000 Electrical Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAttached Test Leads, with Removable 4mm Removable Probe Caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser's Manual \/ Quick Reference Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluke PRV240FS Proving Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTPAK Hanging Strap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour AA Batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstruction Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldSense AC Voltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldSense AC Voltage Resolution\u003c\/td\u003e\n\u003ctd\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldSense AC Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(3 % + 3 counts) [2] [3] 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFildSense AC Current Range\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFildSense AC Current Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFildSense AC Current Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(3 % + 3 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldSense Frequency (Hz) Range\u003c\/td\u003e\n\u003ctd\u003e45 Hz-66Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldSense Frequency (Hz) Resolution\u003c\/td\u003e\n\u003ctd\u003e1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldSense Frequency (Hz) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 2 counts) [3]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts AC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1-year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e61.1 mm x 259.3 mm x 43.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (0.78 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFork Opening\u003c\/td\u003e\n\u003ctd\u003e17.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 °C (14 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Operating\u003c\/td\u003e\n\u003ctd\u003e2,000 m (6,562 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type and Life\u003c\/td\u003e\n\u003ctd\u003e2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"document\" href=\"https:\/\/www.fluke-direct.com\/pdfs\/cache\/www.fluke-direct.com\/t6-1000-prv240fs\/datasheet\/t6-1000-prv240fs-datasheet.pdf\" target=\"_blank\"\u003e\u003cspan class=\"main-color\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003c\/span\u003e for the Fluke T6-1000\/PRV240FS Electrical Tester with FieldSense Technology, 1000V AC \u0026amp; Proving Unit\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043707855004,"sku":"FLUT6-1000\/PRV240FS","price":786.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/fluke-t6-1000-prv240fs-electrical-tester.jpg?v=1633620488","url":"https:\/\/mektronics.com.au\/products\/fluke-t6-1000-prv240fs-electrical-tester-with-fieldsense-technology-1000v-ac-proving-unit","provider":"Mektronics Australia","version":"1.0","type":"link"}