{"product_id":"fluke-t5-600-voltage-continuity-and-current-tester","title":"Fluke T5-600 Voltage, Continuity and Current Tester","description":"\u003cp\u003e\u003cstrong\u003eFluke T5-600 Voltage, Continuity and Current Tester Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe T5-600 Voltage Continuity and Current Tester is a versatile troubleshooting tool for up to 600 V environments. Use it to check voltage, continuity, and current with one compact tool. Just select volts, ohms, or current and the tester does the rest. Its OpenJaw™ current measurement lets you check current up to 100 A without breaking the circuit.\u003c\/p\u003e\n\u003cp\u003eDetachable SlimReach™ test probes are customized for national electrical standards. Plus, its tough test leads accept optional accessories such as clips and specialty probes. The test leads stow neatly in the back of the tester, making it easy to carry in your tool pouch. Add the optional H5 holster and you can clip the T5-1000 onto your belt. For higher voltage applications check out the Fluke T5-1000.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOther useful capabilities:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a compact design with handy probe storage\u003c\/li\u003e\n\u003cli\u003eWithstands a 10 ft. (3 m) drop\u003c\/li\u003e\n\u003cli\u003eIncludes detachable SlimReach™ probe tips that are customized for national electrical standards\u003c\/li\u003e\n\u003cli\u003eCan stay connected much longer than solenoid type testers\u003c\/li\u003e\n\u003cli\u003eOffers Auto-off mode to conserve battery life\u003c\/li\u003e\n\u003cli\u003eFits into an optional holster that attaches to a belt and neatly stows test leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke T5-600 Voltage, Continuity and Current Tester Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable electrical tester automatically measures volts AC and volts DC with precise digital resolution\u003c\/li\u003e\n\u003cli\u003eIncludes easy, accurate OpenJaw™ current measurement\u003c\/li\u003e\n\u003cli\u003eDisplays resistance to 1000 Ω\u003c\/li\u003e\n\u003cli\u003eIncludes a continuity beeper for quick go\/no-go tests\u003c\/li\u003e\n\u003cli\u003eAll inputs are protected to EN61010-1 CAT III 600 V rating. UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke T5-600 Voltage, Continuity and Current Tester Includes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 V Voltage, continuity and current tester\u003c\/li\u003e\n\u003cli\u003e4 mm detachable probes\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke T5-600 Voltage, Continuity and Current Tester Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"productDetailShortDesc\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12.9 mm (0.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\/0 THHN Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range AC rms\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 100.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy AC current (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ± 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAveraging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage range AC\/DC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\u003cspan\u003eAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003e1% ± 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity beeper threshold\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOn at \u0026lt; 25 Ω, off at \u0026gt; 400 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts indicator LED threshold\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGuaranteed on by 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 95% (5°C to 30°C);\u003cbr\u003e0% to 75% (30°C to 40°C);\u003cbr\u003e0% to 45% (40°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust\/water resistance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy)\/°C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V between any terminal and earth ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30.5 x 51 x 203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTwo-years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 hour zinc chloride, 400 hour alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 x AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow battery indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent sensor opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eTest leads\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy duty, flexible leads rated for 1000 V use.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eField replaceable leads terminate in male shrouded banana plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eProbes\u003c\/td\u003e\n\u003ctd\u003eOne red, one black.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDetachable Slim-Reach™ probe tips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStyles\u003c\/td\u003e\n\u003ctd\u003eTP1 Slim Reach™ Test Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043707527324,"sku":"FLUT5-600USA","price":351.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/fluke-flut5600-39662-jpg-300wx300h.jpg?v=1633620468","url":"https:\/\/mektronics.com.au\/products\/fluke-t5-600-voltage-continuity-and-current-tester","provider":"Mektronics Australia","version":"1.0","type":"link"}