{"product_id":"fluke-i6000sflex-ac-current-probe","title":"Fluke i6000sFlex AC Current Probe","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe i6000sflex is an AC current probe utilising the Rogowski principle. It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eElectrical Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent ranges\u003c\/td\u003e\n\u003ctd\u003e60 A \/ 600 A \/ 6000 A AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput sensitivity (AC coupled)\u003c\/td\u003e\n\u003ctd\u003e50 mV \/5 mV \/ 0.5 mV per A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad impedance\u003c\/td\u003e\n\u003ctd\u003e100 kOhm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at +25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of range (45 – 65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity (10% to 100% of range)\u003c\/td\u003e\n\u003ctd\u003e±0.2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e8 mV AC rms (60 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e2 mV AC rms (600\/6000 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 50 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePhase error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ±1° (45 – 65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e±10° (at 20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition sensitivity (with cable \u0026gt; 25 mm from the coupling)\u003c\/td\u003e\n\u003ctd\u003e±2% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field (with cable \u0026gt; 200 mm from the head)\u003c\/td\u003e\n\u003ctd\u003e±1% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e2 x AA MN 1500 LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e400 Hours, low battery indicator or dedicated ext power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.08% of reading per ° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking voltage (see Safety Standards section)\u003c\/td\u003e\n\u003ctd\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHead cable length (double insulated)\u003c\/td\u003e\n\u003ctd\u003e610 mm (24 in) I6000s Flex-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e915 mm (36 in) I6000s Flex-36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead cable diameter\u003c\/td\u003e\n\u003ctd\u003e14.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead bend radius\u003c\/td\u003e\n\u003ctd\u003e38.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length (head to electronics)\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOutput connection\u003c\/td\u003e\n\u003ctd\u003e0.5 m cable terminated with safety BNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSupplied with 4 mm safety plug adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-20 to +90°C (head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-20 to +85°C (electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-40 to +105°C (head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-20 to +85°C (electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e15% to 85% (non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e180 g (head), 190 g (electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eSafety Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBS EN 61010\u003c\/td\u003e\n\u003ctd\u003e1: 2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBS EN 61010\u003c\/td\u003e\n\u003ctd\u003e2-032: 2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBS EN 61010\u003c\/td\u003e\n\u003ctd\u003e031: 2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600 V rms, Category III, Pollution degree 2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC standards\u003c\/td\u003e\n\u003ctd\u003eBS EN 61326: 1998 +A1, A2, and A3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold small-font\"\u003eUse of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eElectrical Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent ranges\u003c\/td\u003e\n\u003ctd\u003e60 A \/ 600 A \/ 6000 A AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput sensitivity (AC coupled)\u003c\/td\u003e\n\u003ctd\u003e50 mV \/5 mV \/ 0.5 mV per A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad impedance\u003c\/td\u003e\n\u003ctd\u003e100 kOhm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at +25°C)\u003c\/td\u003e\n\u003ctd\u003e±1% of range (45 – 65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity (10% to 100% of range)\u003c\/td\u003e\n\u003ctd\u003e±0.2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e8 mV AC rms (60 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e2 mV AC rms (600\/6000 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 50 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePhase error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ±1° (45 – 65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e±10° (at 20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition sensitivity (with cable \u0026gt; 25 mm from the coupling)\u003c\/td\u003e\n\u003ctd\u003e±2% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field (with cable \u0026gt; 200 mm from the head)\u003c\/td\u003e\n\u003ctd\u003e±1% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e2 x AA MN 1500 LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e400 Hours, low battery indicator or dedicated ext power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.08% of reading per ° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking voltage (see Safety Standards section)\u003c\/td\u003e\n\u003ctd\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHead cable length (double insulated)\u003c\/td\u003e\n\u003ctd\u003e610 mm (24 in) I6000s Flex-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e915 mm (36 in) I6000s Flex-36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead cable diameter\u003c\/td\u003e\n\u003ctd\u003e14.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead bend radius\u003c\/td\u003e\n\u003ctd\u003e38.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length (head to electronics)\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOutput connection\u003c\/td\u003e\n\u003ctd\u003e0.5 m cable terminated with safety BNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSupplied with 4 mm safety plug adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-20 to +90°C (head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-20 to +85°C (electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-40 to +105°C (head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-20 to +85°C (electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e15% to 85% (non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e180 g (head), 190 g (electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eSafety Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBS EN 61010\u003c\/td\u003e\n\u003ctd\u003e1: 2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBS EN 61010\u003c\/td\u003e\n\u003ctd\u003e2-032: 2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBS EN 61010\u003c\/td\u003e\n\u003ctd\u003e031: 2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600 V rms, Category III, Pollution degree 2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC standards\u003c\/td\u003e\n\u003ctd\u003eBS EN 61326: 1998 +A1, A2, and A3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold small-font\"\u003eUse of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cp\u003eFluke-i6000s Flex\u003c\/p\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv id=\"ig-product-models\" class=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion\"\u003e\n\u003cdiv class=\"model-desc\"\u003e\n\u003cp\u003eAC Current Probe\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043663257756,"sku":"FLUI6000SFLEX-36","price":1971.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/flui6000sflex-36.jpg?v=1633619758","url":"https:\/\/mektronics.com.au\/products\/fluke-i6000sflex-ac-current-probe","provider":"Mektronics Australia","version":"1.0","type":"link"}