{"product_id":"fluke-connect-installation-tester","title":"Fluke Connect Installation Tester","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 1664 FC Installation Tester is the only tester with \"Insulation PreTest.\" If the tester detects that an appliance is connected to the system under test, it stops the insulation test, helping eliminate accidental damage. The 1664 FC also gives you Fluke Connect\u003csup\u003e®\u003c\/sup\u003e, so you can send test results to your smartphone and collaborate with others. Auto Test makes performs seven tests with one press of the button, reducing the number of manual connections and decreasing the possibility of making errors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Fluke 1664 FC Installation Tester is the only Installation with \"Insulation PreTest,\" which warns you about potentially serious and costly mistakes. If the tester detects that an appliance is connected to the system under test, it will stop the insulation test and provide a visual warning. This helps eliminate accidental damage to peripheral equipment and keeps your customers happy.\u003c\/li\u003e\n\u003cli\u003eStay on the same page even when you and your team are in different places. Fluke Connect allows your 1664 FC Installation Tester to send test results to your smartphone so you can connect and collaborate with others. It's the fastest way to let your team see what you see, helping you get approvals without leaving the field.\u003c\/li\u003e\n\u003cli\u003eFlukeCloud™ storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. Plus you can import the data into Fluke DMS to process and generate certificates. Plus you get world-class data protection. Safe. Secure. Fast. More accurate. All from the power of Fluke Connect.\u003c\/li\u003e\n\u003cli\u003eAuto Test performs 5 required installation tests in one sequence, ensuring compliance with local installation regulations. It reduces the number of manual connections, decreases the possibility of making errors and reduces test time up to 40% from previous Fluke models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInclusions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e6x AA (IEC LR6) cell batteries\u003c\/li\u003e\n\u003cli\u003eC1600 hard carrying case\u003c\/li\u003e\n\u003cli\u003eZero adapter\u003c\/li\u003e\n\u003cli\u003eHeavy duty mains cord\u003c\/li\u003e\n\u003cli\u003eSTD standard test lead set\u003c\/li\u003e\n\u003cli\u003eC1600 hard carrying case\u003c\/li\u003e\n\u003cli\u003ePadded carrying and waist strap\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eTP165X remote control probe and lead\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr id=\"_ctl0_MainContentPlaceHolder_trPrdTabs\"\u003e\n\u003ctd\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv align=\"left\"\u003e\n\u003cdiv id=\"_ctl0_MainContentPlaceHolder_ucTabProduts_radMultPageHome\"\u003e\n\u003cdiv id=\"_ctl0_MainContentPlaceHolder_ucTabProduts_pvFeature\"\u003e\n\u003cdiv\u003e\n\u003ctable align=\"left\" border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr valign=\"top\"\u003e\n\u003ctd valign=\"top\"\u003eThe 1664 FC puts more power in your hands by quickly and efficiently testing to all local regulations, protecting appliances that may be inadvertently connected to the system under test, and making it easy to share test results over your smartphone.\n\u003cul\u003e\n\u003cli\u003eAutotest to test line\/loop impedance, RCD trip current \/ trip time, insulation tests with a single connection and the press of a single button.\u003c\/li\u003e\n\u003cli\u003eAdditional high current loop mode. Faster measurements compared to loop tests with non-trip mode for RCDs.\u003c\/li\u003e\n\u003cli\u003eZ-max memory for loop tests – easy evaluation of the highest loop test value.\u003c\/li\u003e\n\u003cli\u003eUnique zero adapter for fast, always reliable and accurate test lead and mains cord compensation.\u003c\/li\u003e\n\u003cli\u003eFast voltage measurement between L-N, L-PE and N-PE using the mains cord. No need to change measurement connections.\u003c\/li\u003e\n\u003cli\u003eMeasure RCD trip current \u0026amp; trip time in parallel (RCD type AC and A).\u003c\/li\u003e\n\u003cli\u003eTwo measurements at once and a dual display. PEFC or PSC and loop impedance are measured and displayed in parallel, saving you time.\u003c\/li\u003e\n\u003cli\u003eRing testing – select the required input sockets with soft keys – no need to exchange test leads.\u003c\/li\u003e\n\u003cli\u003eAutomatic test start for Loop \u0026amp; RCD tests – as soon as mains voltage is stable it starts testing.\u003c\/li\u003e\n\u003cli\u003eEarth Volt Touchpad detects raised earth voltages \u0026gt;50 V, indicating potential dangerous situations.\u003c\/li\u003e\n\u003cli\u003eSupplied with the safety designed SureGrip™ test leads and clips which gives the user a comfortable, reliable grip and consistent results.\u003c\/li\u003e\n\u003cli\u003eRotary dial knob indicates clearly which function is selected, all in one spot with no complex multi-level menus.\u003c\/li\u003e\n\u003cli\u003eLarge display with backlight, clear symbols and with exceptionally wide viewing angle for easy and safe readings.\u003c\/li\u003e\n\u003cli\u003ePASS\/FAIL indication for RCD test results.\u003c\/li\u003e\n\u003cli\u003eVariable RCD current mode for customized settings.\u003c\/li\u003e\n\u003cli\u003eLoop \u0026amp; line resistance with mΩ resolution.\u003c\/li\u003e\n\u003cli\u003eTest smooth dc sensitive RCDs (Type B).\u003c\/li\u003e\n\u003cli\u003eExtended memory with 3 layers.\u003c\/li\u003e\n\u003cli\u003eUse continuity test currents to measure motor windings.\u003c\/li\u003e\n\u003cli\u003eWithstands a drop of 1 meter.\u003c\/li\u003e\n\u003cli\u003eCompact, lightweight (less than 1.3 kg) and padded neck-strap to free your hands for all day testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy 45 Hz – 66 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.8% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e360 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e660 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eContinuity testing (RLO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRange (autoranging)\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u0026gt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInsulation resistance measurement (RISO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e50-100-250-500-1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy of tTest voltage (at rated test current)\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e+10%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e50 V\u003cbr\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInsulation resistance range\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e20 MΩ \/50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTest current\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eLoop and line impedance (ZI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eProspective earth fault current, PSC test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e1000 A \/ 10 kA (50 kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e1 A \/ 0.1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eComputation\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRCD testing, RCD types tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRCD Type\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eAC¹\u003cbr\u003eG²,S³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eModel 1664\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eA, AC, B\u003csup\u003e5\u003c\/sup\u003e, S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e¹Responds to AC \u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e\u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTripping speed test (ΔT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCurrent settings¹\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMultiplier\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003ex ½, x 1\u003cbr\u003ex 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRCD Type G\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e310 ms\u003cbr\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRCD Type S\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e510 ms\u003cbr\u003e160 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eVAR mode not available for type B.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCurrent range\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e30% to 110% of RCD rated current¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStep size\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e10% of IΔN²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" valign=\"top\"\u003eDwell time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eType G\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e300 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eType S\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e500 ms\/step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSpecified trip current ranges (EN 61008-1)\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003cbr\u003e²5% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNotes\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEarth Resistance Test (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e0.1 Ω \/ 1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePhase Sequence Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eIcon\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cimg alt=\"icon phase sequence indicator \" src=\"http:\/\/www.fluke.com\/NR\/rdonlyres\/0E0FBE6C-9050-4452-B18F-323B25CDE148\/0\/icon_phase_sequence_indicator.png\"\u003e Phase Sequence indicator is active.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e10 x 25 x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight (incl. batteries)\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e1.3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery size, quantity\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eType AA, 6 ea.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSealing\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eComplies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI\/ISA –s82.02.01 2000 and CAN\/CSA c22.2 No. 1010 2nd edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eCAT III \/ 500V; CAT IV 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePerformance\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eEN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043637960860,"sku":"FLUFLK-1664FC\/FVFAU","price":4533.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/fluflk-1664fcfvfau.jpg?v=1633619408","url":"https:\/\/mektronics.com.au\/products\/fluke-connect-installation-tester","provider":"Mektronics Australia","version":"1.0","type":"link"}