{"product_id":"fluke-a3001-fc-wireless-iflexr-ac-current-clamp-kit","title":"Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFluke a3001 FC Wireless iFlex® AC Current Clamp Kit is part of the Fluke Connect® team of wireless test tools\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the a3001 FC Wireless AC Current Module and flexible current probe to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.\u003c\/p\u003e\n\u003cp\u003eYou’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.\u003c\/p\u003e\n\u003cp\u003eFrom short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Module captures up to 65,000 sets of time stamped min\/max\/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.\u003c\/p\u003e\n\u003cp\u003eNow you can take readings on moving machinery, with only the measurement module in harm’s way.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit provides measurement of many common electrical parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurements to 1000V\u003c\/li\u003e\n\u003cli\u003eAC and DC current with 0.01 mA resolution\u003c\/li\u003e\n\u003cli\u003eContinuity, resistance, diode test, capacitance and frequency measurements\u003c\/li\u003e\n\u003cli\u003eMIN\/MAX recording\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, Cat IV 600 V; IP54\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Fluke a3001 FC Wireless iFlex® AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure up to 2500 A AC\u003c\/li\u003e\n\u003cli\u003eUse as a standalone meter or as part of the system\u003c\/li\u003e\n\u003cli\u003eLogging function for recording and saving up to 65,000 readings\u003c\/li\u003e\n\u003cli\u003eInrush function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 3000 FC Series Wireless Multimeter\u003c\/li\u003e\n\u003cli\u003eFluke a3001 FC Wireless iFlex AC Current Module\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eAC175 Alligator Clips\u003c\/li\u003e\n\u003cli\u003eiFlex i2500-10 Flexible Current Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange¹ \/ resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003cbr\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003e 3 \u003c\/span\u003e\u003cspan\u003e4\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 Hz to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. All AC voltage ranges are specified from 1% of range to 100% of range. \u003cbr\u003e2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor \u0026lt; 1.5 at 1000 V.\u003cbr\u003e3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. \u003cbr\u003e4. Do not exceed 107 V-Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage, Continuity, Resistance, Diode Test and Capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.09% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eV\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V \u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.09% + 2\u003cbr\u003e0.15% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e)))\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eMeter beeps at \u0026lt; 25 Ω, beeper detects opens or shorts of 250 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e60.00 kΩ \/ 0.1 kΩ\u003cbr\u003e600.0 kΩ \/ 0.001 MΩ\u003cbr\u003e50.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003cbr\u003e0.5% + 1\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eµF\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF\u003cspan\u003e1 \/ \u003c\/span\u003e1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.2% + 2\u003cbr\u003e10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC and DC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA AC \u003cbr\u003e(45 Hz to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eRange\u003cspan\u003e1\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \/ resolution\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003cspan\u003e3\u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC\u003cspan\u003e2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003cspan\u003e1\u003c\/span\u003e \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003cspan\u003e3\u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. All AC current ranges are specified from 5% of range to 100% of range. \u003cbr\u003e2. Input burden voltage (typical): 400 mA input 2 mV\/mA. \u003cbr\u003e3. 400.0 mA accuracy specified up to 600 mA overload.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \/ resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e99.99 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cspan\u003e1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInput Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-1-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-2-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB, DC to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-3-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOpen Circuit Test Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-4-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 VDC\u003cbr\u003e\u0026lt; 0.9 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-5-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e2.000 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emA Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFused, 44\/100 A, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 mA overload for 2 minutes maximum, 10 minutes rest minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMIN\/MAX Recording Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±12 counts for changes \u0026gt; 350 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±40 counts for changes \u0026gt; 900 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 VDC or AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eΩ fuse protection from A inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44 A (44\/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts, amps, ohms\u003c\/td\u003e\n\u003ctd\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA Alkaline batteries, NEDA 15A IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF communications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRF communication range\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen air, unobstructed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, sheetrock wall\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, concrete wall, or steel electrical enclosure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUp to 3.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy) \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90% (0°C to 35°C)\u003cbr\u003e0% to 75% (35°C to 40°C)\u003cbr\u003e0% to 45% (40°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003cbr\u003eEMI, RFI, EMC, RF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006, EN 61326-2-2:2006\u003cbr\u003eETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489\u003cbr\u003eV1.8.1:2008\u003cbr\u003eFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249\u003cbr\u003eFCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eANSI\/ISA 61010-1 \/ (82.02.01): 3rd edition\u003cbr\u003eCAN\/CSA-C22.2 No 61010-1-12: 3rd edition\u003cbr\u003eUL 61010-1: 3rd edition \u003cbr\u003eIEC\/EN 61010-1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, FCC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e340 g (12 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eNot compatible with Fluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\n\u003ch4\u003eFluke a3001 FC Wireless iFlex® AC Current Module\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 A to 2500 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ±5 digits (5 Hz to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor (50 Hz \/ 60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0 at 1100 A\u003cbr\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCD w\/ backlight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3½ digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog rate\/interval\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 sec minimum\/adjustable by PC or front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15 A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRecord up to 65,000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF communications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eRF communication range\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen air, unobstructed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, sheetrock wall\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, concrete wall or steel electrical enclosure\u003c\/td\u003e\n\u003ctd\u003eUp to 3.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdd 0.1 x (specified accuracy) \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90% at 35°C\u003cbr\u003e75% at 40°C \u003cbr\u003e45% at 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, 600 V CAT IV\/1000 V CAT III, 3rd edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25.4 cm (10 in) coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e.22 kg (8 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eNot compatible with Fluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"event-data-sheets\" href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6002305_6116_ENG_C_W.PDF\" target=\"_blank\"\u003eFluke 3000 FC DMM Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043621707932,"sku":"FLUFLK-A3001FCKIT","price":1100.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/f-3000fc-ac-current-iflex_01a_600x402_aeb658d2-ce86-4205-9f06-b3cd810095b9.jpg?v=1633619071","url":"https:\/\/mektronics.com.au\/products\/fluke-a3001-fc-wireless-iflexr-ac-current-clamp-kit","provider":"Mektronics Australia","version":"1.0","type":"link"}