{"product_id":"fluke-87v-max-dmm-and-pvlead1-mc4-test-leads-bundle","title":"Fluke 87V Solar Tools Kit with 87V Max Digital Multimeter \u0026 Test Leads","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe 87V MAX is the ideal electrical troubleshooting solution for solar inverters, combiner boxes and battery storage systems. The 87V MAX is built with an IP67 rated, industrial-strength case and a removable holster. The holster doubles as a test probe holder for easier, one-handed operation. This meter is fully waterproof and dust proof keep working reliably no matter where your job takes you. Safely connect the Solar PV test leads to the meter to validate voltage from individual panels or a series of panels in a PV array.\u003c\/p\u003e\n\u003cp\u003eKey functions of the solar clamp meter and Solar PV test leads:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure voltage of PV arrays safely and accurately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP67 rated meter can withstand harsh outdoor environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeter is designed to survive drops up to 4-meters (13 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar PV leads comply to IEC \/ EN 61010-031\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWithstands drops up to 4-meters (13 feet) with industrial strength casing and holster\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWaterproof, dustproof IP67 case for the most extreme work sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeter rated to CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar PV test lead sets are designed for use with meters that accept 4mm banana plugs, rated to CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eContents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFluke 87V MAX True-rms Digital Multimeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTL175 TwistGuard® test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC175 Alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e80BK-A temperature probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemovable holster with test lead storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree AA batteries (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePomona PVLEAD1 Solar PV Connector to 4 mm Test Lead Set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 4) true-rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC bandwidth\u003c\/td\u003e\n\u003ctd\u003e20 kHz with low pass filter; 3 dB @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003cbr\u003e(20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003cbr\u003e(20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) true-rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.01 nF to 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003eMaximum duty cycle\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per kHz + 0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–200.0 °C to 1090 °C (–328.0 °F to 1994.0 °F)\u003cbr\u003eexcluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK temperature probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater\u003cbr\u003e(–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eMaximum conductance\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDiagnostics and data storage\u003c\/td\u003e\n\u003ctd\u003ePeak Min\/Max\u003c\/td\u003e\n\u003ctd\u003e250 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading hold\/Auto (Touch) Hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative reference\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003ctd\u003e6000 counts updates 4\/second\u003cbr\u003e19,999 counts in high–resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog bar graph\u003c\/td\u003e\n\u003ctd\u003e32 segments, updates 40\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eTwo level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow pass filter (VFD measurements)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Alert™\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA batteries. 800 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.0 x 10.1 x 21.5 cm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e698.5 g (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% – 90% (0 °C – 35 °C)\u003cbr\u003e0% – 70% (35 °C – 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications: Pomona PVLEAD1 MC4 to 4 mm Test Lead Set\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"536\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"39\" rowspan=\"2\" width=\"81\"\u003e \u003c\/td\u003e\n\u003ctd width=\"191\"\u003ePVLEAD1\u003c\/td\u003e\n\u003ctd width=\"264\"\u003ePVLEAD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" width=\"191\"\u003eMC4 to 4mm Test Lead Set\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eMC4 Solar Clamp Meter Test Lead Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"21\"\u003e\n\u003ctd height=\"21\" width=\"81\"\u003eContact\u003c\/td\u003e\n\u003ctd width=\"191\"\u003eBrass, Nickel Plated\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eBrass, Nickel Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" width=\"81\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"191\"\u003e60”\u003c\/td\u003e\n\u003ctd width=\"264\"\u003e36”, 12”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"39\" rowspan=\"2\" width=\"81\"\u003eVoltage\u003c\/td\u003e\n\u003ctd width=\"191\"\u003eCAT III 1000V,\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eCAT III 1000V,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" width=\"191\"\u003eCAT IV 600V\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eCAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" width=\"81\"\u003eCurrent\u003c\/td\u003e\n\u003ctd width=\"191\"\u003e20 amp\u003c\/td\u003e\n\u003ctd width=\"264\"\u003e20 amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" width=\"81\"\u003eStandards\u003c\/td\u003e\n\u003ctd width=\"191\"\u003eIEC 61010-031\u003c\/td\u003e\n\u003ctd width=\"264\"\u003eIEC 61010-031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":46457674629276,"sku":"FLUFLK-87VMAX-PVLEAD1","price":1312.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/files\/a1305c5f-59ae-4a47-8d77-b2a00119f0cd_original__size.webp?v=1772685421","url":"https:\/\/mektronics.com.au\/products\/fluke-87v-max-dmm-and-pvlead1-mc4-test-leads-bundle","provider":"Mektronics Australia","version":"1.0","type":"link"}