{"product_id":"fluke-80i-110s-ac-dc-current-clamp","title":"Fluke 80i-110s AC\/DC Current Clamp","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081\/001.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent Range: 0.1 to 100A DC or 0.1 to 70A AC\u003c\/li\u003e\n\u003cli\u003eBasic Accuracy (DC to 1kHz):\u003cbr\u003e100mV\/A setting: 50mA to 10A +\/- 3% of reading + 50mA\u003cbr\u003e10mV\/A setting: 50mA to 40A +\/- 4% of reading + 50mA\u003cbr\u003e40A to 80A +\/- 12% of reading + 50mA\u003cbr\u003e80 to 100A +\/- 15% of reading\u003c\/li\u003e\n\u003cli\u003eOutput Signal: 10A range: 100mV\/A | 100A range: 10mV\/A\u003c\/li\u003e\n\u003cli\u003eBandwidth: 1Hz to 20kHz\u003c\/li\u003e\n\u003cli\u003eWorking Voltage: 600V AC rms\u003c\/li\u003e\n\u003cli\u003eMaximum Conductor Size: 11.8 mm (.46 inch) diameter\u003c\/li\u003e\n\u003cli\u003eSafety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNominal current range\u003c\/td\u003e\n\u003ctd\u003e10 A, AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e100 A, AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuous current range\u003c\/td\u003e\n\u003ctd\u003e0.1 A - 10 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 A - 100 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum non-destructive current\u003c\/td\u003e\n\u003ctd\u003e140 A - 2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLowest measurable current\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eBasic accuracy\u003c\/td\u003e\n\u003ctd\u003e100 mV\/A setting: 50 mA to 10 A ±3% of reading +50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e10 mV\/A setting: 50 mA to 40 A ±4% of reading +50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e40 A to 80 A ±12% of reading +50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e80 to 100 A ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUseable frequency\u003c\/td\u003e\n\u003ctd\u003eDC - 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOutput level(s)\u003c\/td\u003e\n\u003ctd\u003e10 A range: 100 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e100 A range: 10 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero error adjustment\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCAT II, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eCAT III, 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e9 V, 55 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum conductor diameter\u003c\/td\u003e\n\u003ctd\u003e11.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput cable length\u003c\/td\u003e\n\u003ctd\u003e1.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBNC adapter\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043610468508,"sku":"FLU80I-110S","price":1688.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/80i-110s.png?v=1633618884","url":"https:\/\/mektronics.com.au\/products\/fluke-80i-110s-ac-dc-current-clamp","provider":"Mektronics Australia","version":"1.0","type":"link"}