{"product_id":"fluke-721ex-1630-precision-pressure-calibrator","title":"Fluke 721Ex-1630 Precision Pressure Calibrator","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe ideal tool for gas custody transfer applications in potentially explosive atmospheres is the Fluke 721Ex Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eThe 721Ex can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)\u003c\/li\u003e\n\u003cli\u003eIdeal for gas flow calibration (custody transfer) applications\u003c\/li\u003e\n\u003cli\u003eTwo isolated, stainless steel, pressure sensors with 0.025 % accuracy\u003c\/li\u003e\n\u003cli\u003ePt100 RTD input for temperature measurement, (probe optional)\u003c\/li\u003e\n\u003cli\u003eSwitch test on both pressure inputs\u003c\/li\u003e\n\u003cli\u003ePressure displayed in the user’s choice of 19 engineering units\u003c\/li\u003e\n\u003cli\u003eLarge backlit graphic display can display up to three inputs simultaneously\u003c\/li\u003e\n\u003cli\u003eStore five instrument setups for recall and use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInclusions\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\"\u003e16 psig, 3000 psig, dual sensor pressure calibrator\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eFour (4) AA batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003cli\u003eTraceable calibration certificate\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721Ex-1630\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan\u003eLow pressure sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan\u003eHigh pressure sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +3000 psi,\u003cbr\u003e0.00 bar to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi, \u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument setup recall\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eLast used on power-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eOperating temperature -10°C to +45°C\u003cbr\u003eStorage temperature (without batteries) -20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e6.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026gt;35 hours, typical usage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries required\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e(4) Standard AA cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e03539 kg (1 lb 3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\/ports pressure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTwo, 1\/8 in NPT, 700P Series Pressure Module; RTD Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eElectrical and Temperature Measurement 1-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA measure\u003c\/td\u003e\n\u003ctd\u003e0 to 24 mA\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.002mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eTemperature Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eAvailable Pressure Engineering Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003epsi, bar, mbar, kPa, kgcm2, cmH\u003cspan\u003e2\u003c\/span\u003eO @ 4°C, cmH\u003cspan\u003e2\u003c\/span\u003eO @ 20°C, mH\u003cspan\u003e2\u003c\/span\u003eO @ 4°C, mH\u003cspan\u003e2\u003c\/span\u003eO @ 20°C, inH\u003cspan\u003e2\u003c\/span\u003eO @ 4°C, inH\u003cspan\u003e2\u003c\/span\u003eO @ 20°C, inH\u003cspan\u003e2\u003c\/span\u003eO @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH\u003cspan\u003e2\u003c\/span\u003eO @ 4°C, ftH\u003cspan\u003e2\u003c\/span\u003eO @ 20°C, ftH\u003cspan\u003e2\u003c\/span\u003eO @ 60°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eAvailable Pressure Engineering Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003eATEX\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eEx ia IIB T3 Gb (Ta= -10… +45 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eKEMA 10 ATEX 0168X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003eIECEx\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eEx ia IIB T3 Gb (Ta= -10…+45 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eII 2 G IECEx CSA 10.0013X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6000077_6110_ENG_B_W.PDF\" target=\"_blank\"\u003eData Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043579666588,"sku":"FLU721EX-1630","price":7596.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/flu721ex-1630.jpg?v=1633618370","url":"https:\/\/mektronics.com.au\/products\/fluke-721ex-1630-precision-pressure-calibrator","provider":"Mektronics Australia","version":"1.0","type":"link"}