{"product_id":"fluke-705-loop-calibrator","title":"Fluke 705 Loop Calibrator","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFluke Loop Calibrator\u003c\/span\u003e. This feature-rich solution to loop calibration, maintenance and repair offers:\u003c\/p\u003e\n\u003cul class=\"prdplaintext\"\u003e\n\u003cli\u003eA large display and simple, pushbutton interface for ease of use.\u003c\/li\u003e\n\u003cli\u003eSimultaneous mA and % readout for quick, easy interpretation of readings.\u003c\/li\u003e\n\u003cli\u003emA accuracy of 0.02%\u003c\/li\u003e\n\u003cli\u003ePush button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.\u003c\/li\u003e\n\u003cli\u003e\"Span Check\" for fast confirmation of zero and span.\u003c\/li\u003e\n\u003cli\u003eSelectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.\u003c\/li\u003e\n\u003cli\u003e24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.\u003c\/li\u003e\n\u003cli\u003eSingle 9V battery that is easily changed.\u003c\/li\u003e\n\u003cli\u003e0 - 20 mA or 4 - 20 mA default start up modes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"prdplaintext\"\u003e\n\u003cli\u003emA sourcing, simulation and measurement\u003c\/li\u003e\n\u003cli\u003e0.02% accuracy and 0.001 mA resolution\u003c\/li\u003e\n\u003cli\u003eSimultaneous mA and % of span display\u003c\/li\u003e\n\u003cli\u003eSelectable step or ramp outputs\u003c\/li\u003e\n\u003cli\u003e24 V Loop supply with mA measure\u003c\/li\u003e\n\u003cli\u003e0-28 VDC measurement to check Loop Voltage\u003c\/li\u003e\n\u003cli\u003eEasy battery exchange without opening the case\u003c\/li\u003e\n\u003cli\u003eCompact case with separate protective holster\u003c\/li\u003e\n\u003cli\u003eThree year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003eAC70A Alligator Clips\u003c\/li\u003e\n\u003cli\u003eC10 protective yellow holster with Flex-Stand™\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003cli\u003eTL75 safety-designed test lead set\u003c\/li\u003e\n\u003cli\u003eNIST- traceable calibration report and data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.02% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent sourcing\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive capability\u003c\/td\u003e\n\u003ctd\u003e1000 Ω @ 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent simulation\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA or 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExt. loop voltage requirement\u003c\/td\u003e\n\u003ctd\u003e12-30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWhile measuring mA, 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 28 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% Rdg + 2 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 18°C, 28°C to 55°C, ±.005% of range per°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1:1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN50082-1:1992 and EN55022:1994 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e152 x 70 x 41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e340 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne 9 V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and vibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eper MIL-T-28800 for a Class 2 Instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay current and % of span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto step, auto ramp\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan check\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca class=\"event-data-sheets\" href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/2574106_6110_eng_a_w.pdf\" target=\"_blank\"\u003eLoop Calibrators Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043569901724,"sku":"FLU705","price":1913.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/flu705.jpg?v=1633618169","url":"https:\/\/mektronics.com.au\/products\/fluke-705-loop-calibrator","provider":"Mektronics Australia","version":"1.0","type":"link"}