{"product_id":"fluke-700g-pressure-gauge-calibrator-15-psig","title":"Fluke 700G Pressure Gauge Calibrator 15 Psig","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eWith best-in-class accuracy and measurements, the Fluke 700G series precision pressure test gauges were designed to handle all of your pressure calibration needs. The 700G series pressure test gauges are rugged and easy to use, with twenty three models ranging from ±10 in H2O\/20 mbar to 10,000 psi\/690 bar including absolute pressure ranges. When combined with the Fluke 700PTPK or 700HTPK you’ve got a complete pressure testing solution for up to 600 psi (40 bar) with the PTP-1 pneumatic pump and up to 10,000 psi (690 bar) with the HTP-2 hydraulic pump.\u003c\/p\u003e\n\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision pressure measurement from ±10 in H2O\/20 mbar to 10,000 psi\/690 bar\u003c\/li\u003e\n\u003cli\u003eAbsolute pressure measurement ranges 15, 30, 100, 300 psia\u003c\/li\u003e\n\u003cli\u003eAccuracy to 0.05 % of full scale\u003c\/li\u003e\n\u003cli\u003eReference class gauge accuracies to 0.04 % of reading\u003c\/li\u003e\n\u003cli\u003eEasy to use, rugged construction for reliable performance\u003c\/li\u003e\n\u003cli\u003eCSA; Class 1, Div 2, Groups A-D rating\u003c\/li\u003e\n\u003cli\u003eATEX rating: II 3 G Ex nA IIB T6\u003c\/li\u003e\n\u003cli\u003eCombine with the 700PTPK or 700HTPK pump kits for a complete pressure testing solution for up to 600 psi (40 bar) with the PTP-1 pneumatic pump and up to 10,000 psi (690 bar) with the HTP-2 hydraulic pump\u003c\/li\u003e\n\u003cli\u003eLog up to 8,493 pressure measurements to memory (requires 700G\/TRACK software)\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eBurst Pressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G01\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 inH\u003cspan\u003e2\u003c\/span\u003eO\u003cbr\u003e-20 mbar to 20 mbar\u003c\/td\u003e\n\u003ctd\u003e0.001 inH\u003cspan\u003e2\u003c\/span\u003eO,\u003cbr\u003e0.001 mbar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.1% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e3 psi,\u003cbr\u003e210 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G02\u003c\/td\u003e\n\u003ctd\u003e-1 to +1 psi,\u003cbr\u003e-70 mbar to 70 mbar\u003c\/td\u003e\n\u003ctd\u003e0.0001 psi,\u003cbr\u003e0.001 mbar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.1% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e5 psi,\u003cbr\u003e350 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G04\u003c\/td\u003e\n\u003ctd\u003e-14 to 15 psi,\u003cbr\u003e-0.97 to 1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e60 psi,\u003cbr\u003e4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G05\u003c\/td\u003e\n\u003ctd\u003e-14 to 30 psi,\u003cbr\u003e-0.97 to 2 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e120 psi,\u003cbr\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G06\u003c\/td\u003e\n\u003ctd\u003e-12 to 100 psi,\u003cbr\u003e-0.83 to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e26 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G27\u003c\/td\u003e\n\u003ctd\u003e-12 to 300 psi,\u003cbr\u003e-0.83 to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e1200 psi,\u003cbr\u003e80 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G07\u003c\/td\u003e\n\u003ctd\u003e-12 to 500 psi,\u003cbr\u003e-0.83 to 34 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e2000 psi,\u003cbr\u003e138 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G08\u003c\/td\u003e\n\u003ctd\u003e-14 to 1000 psi,\u003cbr\u003e-0.97 to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e4000 psi,\u003cbr\u003e266 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G10\u003c\/td\u003e\n\u003ctd\u003e-14 to 2000 psi,\u003cbr\u003e-.97 bar to 140 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e8000 psi,\u003cbr\u003e550 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G29\u003c\/td\u003e\n\u003ctd\u003e-14 to 3000 psi,\u003cbr\u003e-0.97 to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G30\u003c\/td\u003e\n\u003ctd\u003e-14 to 5000 psi,\u003cbr\u003e-0.97 to 340 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G31\u003c\/td\u003e\n\u003ctd\u003e-14 to 10000 psi,\u003cbr\u003e-0.97 to 690 bar\u003c\/td\u003e\n\u003ctd\u003e1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e20000 psi,\u003cbr\u003e1035 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA4\u003c\/td\u003e\n\u003ctd\u003e0 to 15 psia,\u003cbr\u003e0 to 1 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e60 psi,\u003cbr\u003e4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA5\u003c\/td\u003e\n\u003ctd\u003e0 to 30 psia\u003cbr\u003e0 to 2 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e120 psi,\u003cbr\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA6\u003c\/td\u003e\n\u003ctd\u003e0 to 100 psia,\u003cbr\u003e0 to 6.9 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e27 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA27\u003c\/td\u003e\n\u003ctd\u003e0 to 300 psia,\u003cbr\u003e0 to 20 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e1200 psi,\u003cbr\u003e80 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG05\u003c\/td\u003e\n\u003ctd\u003e-14 to +30 psi,\u003cbr\u003e-0.97 to +2 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e90 psi,\u003cbr\u003e6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG06\u003c\/td\u003e\n\u003ctd\u003e-12 to 100 psi,\u003cbr\u003e-0.83 to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e27 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG07\u003c\/td\u003e\n\u003ctd\u003e-12 to 500 psi,\u003cbr\u003e-0.83 to 34\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e2000 psi,\u003cbr\u003e138 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG08\u003c\/td\u003e\n\u003ctd\u003e-14 to 1000 psi,\u003cbr\u003e-0.97 to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e4000 psi,\u003cbr\u003e275 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG29\u003c\/td\u003e\n\u003ctd\u003e-14 to 3000 psi,\u003cbr\u003e-0.97 to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG30\u003c\/td\u003e\n\u003ctd\u003e-14 to 5000 psi,\u003cbr\u003e-0.97 to 340 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e15000 psi,\u003cbr\u003e1035 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG31\u003c\/td\u003e\n\u003ctd\u003e-14 to 10000 psi,\u003cbr\u003e-0.97 to 690 bar\u003c\/td\u003e\n\u003ctd\u003e1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e20000 psi,\u003cbr\u003e1380 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e700R Ranges: Temperature Compensation 0 e °C to 50 °C (32 °F to 122 °F) to rated accuracy.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFor temperatures from -10 °C to 0 °C and 50 °C to 55 °C, add .005% FS\/ °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\u003cth\u003eMedia compatibility\u003c\/th\u003e\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e10 inH\u003cspan\u003e2\u003c\/span\u003eO, 1, 15, 30 psi: any clean dry non-corrosive gas\u003c\/li\u003e\n\u003cli\u003e100, 300, 500, 1000 psi: any liquids or gases compatible with 316 stainless steel and above 1000 psi: any non-flammable, non-toxic, non-explosive, non-oxidizing liquid or gas compatible with 316 stainless steel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\u003cth colspan=\"2\"\u003eMechanical Specifications\u003c\/th\u003e\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e12.7 x 11.4 x 3.7 cm (5 x 4.5 x 1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure connection\u003c\/td\u003e\n\u003ctd\u003e¼ in NPT Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\/Weight\u003c\/td\u003e\n\u003ctd\u003eCast ZNAL 0.56 kg (1.22 lb) with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-1\/2 digits, 16.53 mm (0.65 in) high 20-segment bar graph, 0 to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eThree (3) AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"event-data-sheets\" href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/4131179_6110_ENG_A_W.PDF\" target=\"_blank\"\u003e700G Pressure Test Gauge Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043563348124,"sku":"FLU700G04","price":1661.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/flu700g.jpg?v=1633618070","url":"https:\/\/mektronics.com.au\/products\/fluke-700g-pressure-gauge-calibrator-15-psig","provider":"Mektronics Australia","version":"1.0","type":"link"}