{"product_id":"fluke-64-max-ir-thermometer","title":"Fluke 64 Max IR Thermometer","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 64 MAX thermometer has the precision you need to do your job accurately and will not break the budget. Designed and tested to survive a 3 meter drop, you can count on this lightweight, compact infrared thermometer to work when you need it to work – even in the harshest environments and when you're not able to be there.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrecise laser technology for more accurate and repeatable measurements: Temperature accuracy of up to ± 1â„ƒ or ± 1% of reading whichever is greater with 20:1 distance to spot ratio\u003c\/li\u003e\n\u003cli\u003eFlashlight and large, easy-to-read backlit LCD display for easy viewing even in dark environment\u003c\/li\u003e\n\u003cli\u003eIP54 rated for extra protection against airborne contaminants\u003c\/li\u003e\n\u003cli\u003eGet your tool to work when you can't - set time and desired interval between measurements and Auto Capture will capture spot temperatures unattended\u003c\/li\u003e\n\u003cli\u003e99 data point logging\u003c\/li\u003e\n\u003cli\u003e30 hour battery life so your tool can perform as long as you need it to\u003c\/li\u003e\n\u003cli\u003eDisplays the minimum, maximum or average temperature, or the difference between two measurements\u003c\/li\u003e\n\u003cli\u003eHi and Lo alarms for rapid display of measurements outside set limits\u003c\/li\u003e\n\u003cli\u003eSmall and lightweight design fits easily into your tool box\u003c\/li\u003e\n\u003cli\u003ePowered by one (1) AA alkaline battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"block-system-main\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"fluke-product-display-content-tabs\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"specs-tab\"\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey features\u003c\/td\u003e\n\u003ctd\u003e64 MAX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 600 °C\u003cbr\u003e(-22 °F to 1112 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Calibration geometry with ambient temperature 23 °C +\/- 2 °C\u003c\/td\u003e\n\u003ctd\u003e± 1.0 °C or ± 1.0 % of reading, whichever is greater\u003cbr\u003e± 2.0 °C at -10 °C to 0 °C\u003cbr\u003e± 3.0 °C at -30 °C to -10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Resolution\u003c\/td\u003e\n\u003ctd\u003e20 : 1\u003cbr\u003e(calculated at 90 % energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (95 %)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Response\u003c\/td\u003e\n\u003ctd\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.2 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (% of reading)\u003c\/td\u003e\n\u003ctd\u003e± 0.5% of reading or ± 0.5 °C (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Capture\u003c\/td\u003e\n\u003ctd\u003eSet time and interval to capture up to 99 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal memory\u003c\/td\u003e\n\u003ctd\u003e99 data point logging capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlashlight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1 AA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e30 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 60 °C (-4 °F to 140 °F) (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon- condensing @ ≤ 10 °C (50 °F)\u003cbr\u003e≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)\u003cbr\u003e≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)\u003cbr\u003e≤ 45 % RH @ 40 °C 104 °F to 50 °C (122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Resolution\u003c\/td\u003e\n\u003ctd\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImplement Standard\u003c\/td\u003e\n\u003ctd\u003eQ\/ASF01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 60825-1 Class 2, 650 nm, \u0026lt; 1 mW \u003cimg alt=\"laser class 2 safety certification \" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/laserclass2_blk.png\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043561840796,"sku":"FLU64MAX","price":415.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/64_max_product_image_638x1024px_e_nr-22125-500x500.jpg?v=1633618027","url":"https:\/\/mektronics.com.au\/products\/fluke-64-max-ir-thermometer","provider":"Mektronics Australia","version":"1.0","type":"link"}