{"product_id":"fluke-6200-2-portable-appliance-testers","title":"Fluke 6200-2 Portable Appliance Testers","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 6200-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day.  The 6200-2 is designed to enable you to work faster without compromising safety – yours or your customer’s.\u003c\/p\u003e\n\u003cp\u003eOne-Touch Solution…Pre-set test routines are initiated from a single button. This not only simplifies testing but also facilitates a faster, more efficient way of working.\u003c\/p\u003e\n\u003cp\u003eLow Weight…Weighing approximately 3 kg, the 6200-2 is lightweight and easy to carry when working on-site. The hard rugged carrying case (supplied) not only offers protection during transit but also includes extra storage space for accessories and other tools.\u003c\/p\u003e\n\u003cp\u003eSmall Size…This portable appliance testers is also extremely compact, and has Fluke’s traditional ruggedness to be able to withstand working in the field. Packed with all the features you need for testing portable appliances, a Fluke PAT tester is a complete all-in-one solution.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated key for each test for ‘one-touch’ testing\u003c\/li\u003e\n\u003cli\u003ePre-set pass\/fail levels to save time\u003c\/li\u003e\n\u003cli\u003eLarge backlit display for easy reading\u003c\/li\u003e\n\u003cli\u003eSingle mains socket for appliance connection\u003c\/li\u003e\n\u003cli\u003eSeparate IEC socket for easy mains\/extension lead testing\u003c\/li\u003e\n\u003cli\u003eDetachable test leads for quick field replacement\u003c\/li\u003e\n\u003cli\u003eIntegral carrying handle\u003c\/li\u003e\n\u003cli\u003eUSB port for data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 6200-2 Portable Appliance Tester\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eTest lead\u003c\/li\u003e\n\u003cli\u003eTest probe\u003c\/li\u003e\n\u003cli\u003eCrocodile clip\u003c\/li\u003e\n\u003cli\u003eMains cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTest specifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThe accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBetween 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eThe measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003ePower-on test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThe test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e90 V to 264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance      \u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MΩ \/\/ 2.2 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input mains voltage\u003c\/td\u003e\n\u003ctd\u003e264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eEarth bond test (R pe)\u003c\/td\u003e\n\u003ctd\u003eDisplay Range\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (after bond test zeroing)\u003c\/td\u003e\n\u003ctd\u003e±(2.5% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e200 mA AC -0% +40% into 1.99 Ω\u003cbr\u003e25 A AC ±20% into 25 mΩ at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 4 V AC, \u0026lt; 24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBond test zeroing\u003c\/td\u003e\n\u003ctd\u003ecan subtract up to 1.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\"\u003eInsulation test (R iso)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 299 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2 counts) from 0.1 to 300 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ (0 to 19.99 MΩ)\u003cbr\u003e0.1 MΩ (20 to 199.9 MΩ)\u003cbr\u003e1 MΩ (200 to 299 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd\u003e500 V DC -0% + 10% at 500 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 mA at 500 kΩ load, \u0026lt; 15 mA at 0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5 s for 1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. capacitive load\u003c\/td\u003e\n\u003ctd\u003eOperational up to 1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eTouch current test\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 1.99 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(4% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance (via probe)\u003c\/td\u003e\n\u003ctd\u003e2 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd\u003eProbe*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSubstitute leakage current test\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2.5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e100 V AC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eLoad\/leakage test: load current\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 A to 13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(4% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eLoad\/leakage test: load power\u003c\/td\u003e\n\u003ctd\u003eDisplay range 230 V Mains\u003c\/td\u003e\n\u003ctd\u003e0.0 VA to 3.2 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy \u003c\/td\u003e\n\u003ctd\u003e±(5% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 VA (0 to 999 VA), 0.1 kVA (\u0026gt;1.0 kVA)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eLoad\/leakage test: leakage current\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003ePELV test\u003c\/td\u003e\n\u003ctd\u003eAccuracy at 50 Hz\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003e300 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning threshold\u003c\/td\u003e\n\u003ctd\u003e25 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e*The appliance under test is energized at mains potential.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003eNon condensing \u0026lt;10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e95% from 10 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75% from 30 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSafety specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eComplies with EN61010-1 3rd edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT II, 300 V, pol 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and general specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 x 275 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e230 V +10% -15%, 50 Hz ±2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (tester)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e13 W typical (idle)\u003cbr\u003e60 W max. during 25A Bond test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion\u003c\/td\u003e\n\u003ctd\u003e70 °C @ 95% RH for 5 days max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 up to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP-40 (enclosure), IP-20 (connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with EN61326-1, portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI Immunity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 V\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043568558236,"sku":"FLU6200-2AU","price":3511.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/flu6200-2au.jpg?v=1633618134","url":"https:\/\/mektronics.com.au\/products\/fluke-6200-2-portable-appliance-testers","provider":"Mektronics Australia","version":"1.0","type":"link"}