{"product_id":"fluke-369-fc-leakage-current-clamp-meter","title":"Fluke 369 FC Leakage Current Clamp Meter","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReduce downtime – Find leakage currents without taking equipment offline.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 369 FC has an oversize 61 mm jaw for work with extra-large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eThe 369 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 369 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures\u003c\/p\u003e\n\u003cstrong\u003e includes\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLeakage Clamp Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSoft case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety Manual\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBatteries: 2 AA\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e Features\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eThe Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.\u003c\/li\u003e\n\u003cli\u003eThe Fluke 369 FC has an oversize 61 mm jaw for work with extra-large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eThe 369 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 369 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003e Specifications\u003c\/strong\u003e\n\u003cdiv id=\"product-specs\" data-readmore=\"\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement function\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAlternating current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC ampere range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange selection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003emA \/ A: manual selection\u003cbr\u003e3 mA \/ 30 mA \/ 300 mA: automatic selection\u003cbr\u003e3 A \/ 30 A \/ 60 A: automatic selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eRange \/ Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e3 mA¹ \/ 0.001 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e30 mA \/ 0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e300 mA \/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e3 A \/ 0.001 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e30 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e60 A \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²\u003c\/td\u003e\n\u003ctd\u003e3 mA – 30 A\u003cbr\u003e60 A\u003c\/td\u003e\n\u003ctd\u003e1% + 5 digits\u003cbr\u003e2% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAfter calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.\u003cbr\u003e¹The minimum value is 10 μA rms.\u003cbr\u003e²Outside of the TC \/ °C 18 °C to 28 °C, 0.02 + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePhysical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital readout: 3300 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay refresh rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 times \/ sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum conductor diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e257 x 116 x 46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, IEC LR6, NEDA 15A, alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eExpected battery life, without using backlight and spotlight, is more than 150 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic shut-down\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeter automatically shuts down after 15 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSafety and Environmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral safety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement safety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-032: CAT III 600 V \/ CAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eNon-condensing (\u0026lt;10 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e90% relative humidity (10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e75% relative humidity (30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e45% relative humidity (40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent sensor action category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61557-13: Class 1, ≤100 A \/ m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eElectromagnetic compatibility (EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInternational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61326-1\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIndustrial Electromagnetic Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCISPR 11\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGroup 1 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup 1\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGenerated inside the equipment and \/ or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass B\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEquipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.\u003cbr\u003eKorea (KCC): Class A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass A\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThis product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.\u003cbr\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ca class=\"event-data-sheets\" href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6008008_0000_ENG_B_W.PDF\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003ca class=\"event-data-sheets\" href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6008008_0000_ENG_B_W.PDF\" target=\"_blank\"\u003e368\/368 and 369\/369 FC Data Sheet_6008008b_EN\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043550568604,"sku":"FLU369FC","price":2225.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/flu396fc.jpg?v=1633617788","url":"https:\/\/mektronics.com.au\/products\/fluke-369-fc-leakage-current-clamp-meter","provider":"Mektronics Australia","version":"1.0","type":"link"}