{"product_id":"fluke-3000-fc-tpak-combo-kit","title":"Fluke 3000 FC\/TPAK Combo Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe FLK-3000FC\/TPAK from Fluke is a true RMS wireless multimeter combo kit. It improves safety and efficiency with its testing methods. The Fluke 3000 FC multimeter with Fluke Connect application and ShareLive video call enables all the facts to be right in the field. This multimeter is the ideal solution for professional technicians with its precision, reliability and ease of use. It is independently tested for safe use in CAT IV 600V\/ CAT III 1000V environments. The Fluke 3000 FC has all the features need to troubleshoot and repair many problems in electrical and electronic systems. This multimeter gives true RMS voltage and current measurements, 6000 count resolution, manual and automatic ranging and provides frequency, capacitance, resistance, continuity and diode measurements. In addition, it provides higher 0.09% basic accuracy. It complies with ANSI\/ISA 61010-1\/(82.02.01), CAN\/CSA-C22.2 number 61010-1-12, UL 61010-1, IEC\/EN 61010-1:2010, CSA, FCC \u0026amp; CE standards.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnables work safely near electrical panels while wearing less PPE\u003c\/li\u003e\n\u003cli\u003eAdds laptop and go from logging to analysis and diagnosis\u003c\/li\u003e\n\u003cli\u003eRecord over time using Fluke Connect wireless modules and monitor circuits\u003c\/li\u003e\n\u003cli\u003e600mV to 1000V AC voltage measurement and 600mV to 1000V DC voltage measurement\u003c\/li\u003e\n\u003cli\u003e60mA to 400mA (45Hz to 1KHz) AC current measurement and 60mA to 400mA DC current measurement\u003c\/li\u003e\n\u003cli\u003e600 ohm to 50Mohm resistance measurement and 99.9 Hz 99.99KHz frequency measurement\u003c\/li\u003e\n\u003cli\u003ePerforms analysis with PC and share results using Fluke Cloud storage and ShareLive video call\u003c\/li\u003e\n\u003cli\u003eLarge digit display with analogue bar graph, display backlight for work in dark areas\u003c\/li\u003e\n\u003cli\u003eDimension is 4.75cm x 9.3cm x 20.7cm (H x W x L) and weight is 340g\u003c\/li\u003e\n\u003cli\u003eOperating temperature range from -10°C to 50°C, IP54 and pollution degree 2 rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest \u0026amp; Measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 3000 FC True-rms digital multimeter with backlight\u003c\/li\u003e\n\u003cli\u003eFluke TL75 test leads\u003c\/li\u003e\n\u003cli\u003eFluke C35 lightweight soft carrying case\u003c\/li\u003e\n\u003cli\u003eToolPak™ magnetic meter hanger\u003c\/li\u003e\n\u003cli\u003eInstalled batteries\u003c\/li\u003e\n\u003cli\u003eUser's manual CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange¹ \/ resolution\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003cbr\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003cspan\u003e2\u003c\/span\u003e \u003cspan\u003e3\u003c\/span\u003e \u003cspan\u003e4\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 Hz to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. AC voltage ranges are specified from 1% of range to 100% of range.\u003cbr\u003e2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor \u0026lt; 1.5 at 1000 V.\u003cbr\u003e3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.\u003cbr\u003e4. Do not exceed 107 V-Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage, Continuity, Resistance, Diode Test and Capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.09% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eV\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.09% + 2\u003cbr\u003e0.15% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e)))\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eMeter beeps at \u0026lt; 25 Ω, beeper detects opens or shorts of 250 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e60.00 kΩ \/ 0.1 kΩ\u003cbr\u003e600.0 kΩ \/ 0.001 MΩ\u003cbr\u003e50.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003cbr\u003e0.5% + 1\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eµF\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange \/ resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF\u003cspan\u003e1 \/ \u003c\/span\u003e1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.2% + 2\u003cbr\u003e10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC and DC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA AC\u003cbr\u003e(45 Hz to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eRange\u003cspan\u003e1\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \/ resolution\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003cspan\u003e3 \u003c\/span\u003e\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC\u003cspan\u003e2\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eRange\u003cspan\u003e1\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \/ resolution\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\u003cspan\u003e3\u003c\/span\u003e \/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. All AC current ranges are specified from 5% of range to 100% of range.\u003cbr\u003e2. Input burden voltage (typical): 400 mA input 2 mV\/mA.\u003cbr\u003e3. 400.0 mA accuracy specified up to 600 mA overload.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \/ resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e99.99 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cspan\u003e1\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInput Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-1-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-2-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB, DC to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-3-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOpen Circuit Test Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-4-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 V DC\u003cbr\u003e\u0026lt; 0.9 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-5-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e2.000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emA Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFused, 44\/100 A, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 mA overload for 2 minutes maximum, 10 minutes rest minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMIN\/MAX Recording Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 12 counts for changes \u0026gt; 350 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 40 counts for changes \u0026gt; 900 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V DC or AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eΩ fuse protection from A inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44 A (44\/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts, amps, ohms\u003c\/td\u003e\n\u003ctd\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA Alkaline batteries, NEDA 15A IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF communications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRF communication range\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen air, unobstructed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, sheetrock wall\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, concrete wall, or steel electrical enclosure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUp to 3.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 X (specified accuracy) \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90% (0°C to 35°C)\u003cbr\u003e0% to 75% (35°C to 40°C)\u003cbr\u003e0% to 45% (40°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003cbr\u003eEMI, RFI, EMC, RF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326–1:2006, EN 61326–2–2:2006\u003cbr\u003eETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489\u003cbr\u003eV1.8.1:2008\u003cbr\u003eFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249\u003cbr\u003eFCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eANSI \/ ISA 61010–1 \/ (82.02.01): 3rd edition\u003cbr\u003eCAN \/ CSA-C22.2 No 61010-1-12: 3rd edition\u003cbr\u003eUL 61010–1: 3rd edition\u003cbr\u003eIEC \/ EN 61010–1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, FCC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e340 g (12 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eNot compatible with Fluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"event-data-sheets\" href=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/6002305_6116_ENG_C_W.PDF\" target=\"_blank\"\u003eFluke 3000 FC DMM Data Sheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":41043547193500,"sku":"FLUFLK-3000FC\/TPAK","price":864.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/products\/fluflk-3000f.jpg?v=1633617704","url":"https:\/\/mektronics.com.au\/products\/fluke-3000-fc-tpak-combo-kit","provider":"Mektronics Australia","version":"1.0","type":"link"}