{"product_id":"fluke-1673-fc-aus-ftt-installation-tester-aus-trutest","title":"Fluke 1673 FC AUS FTT Multifunction Installation Tester AUS + TruTest","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 1670 Series Multifunction Installation Testers will revolutionize the way you work. With an ergonomic design, seamless user interface, integrated data management capabilities, wireless connectivity (1673 FC and 1674 FC), and comprehensive reporting software, the 1670 Series sets the new standard for an integrated installation testing solution.\u003c\/p\u003e\n\u003cp\u003eReliable installation testing is essential for ensuring the safety, optimal functionality, and integrity of a facility’s electrical systems. The 1670 Series' rugged design allows you to verify the safety of electrical installations in domestic, commercial, and industrial applications while meeting the requirements of IEC\/HD 60364-6 and all relevant local installation test standards.\u003c\/p\u003e\n\u003cp\u003eWith the 1670 Series, you’ll be able to perform your required testing faster and reduce the time you spend on documentation, all while having the ultimate confidence in the data you’re collecting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified User Interface and Testing Setup\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1670 Series takes data management to the next level streamlining test set up and preparation with an advanced bidirectional user interface. When setting up your project, the hierarchical tree topology for clients, sites, distribution boards, circuits, and test points can be easily customized using the high-resolution color touchscreen, a smart device, or by PC. Edit, add, delete, or modify information directly on the tool as you test to ensure accurate data, or transfer updates to your tester via the Fluke Connect™️ mobile app or TruTest™️ desktop software. Easy-to-read test tables help you quickly see that you are capturing the right measurement data at the right test point, every time. Now you can spend less time setting up your tester and organizing data, giving you more time to perform valuable testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerform All Required Tests up to 30% Faster\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation testing can be a time-consuming process. It often requires repetitive, manual test setups that can be frustrating and introduce the opportunity for errors.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1670 Series leverages a unique Auto Test function (1673 FC \/ 1674 FC) that enables you to run through an entire installation test sequence at the touch of a button. An integrated help function provides a visual connection guide to help ensure measurement success. Automatic measurement validation, with user-defined limit warnings, compares test results to the relevant standards and provides you with an immediate visual pass\/fail indication to quickly identify potential issues. Eliminating manual testing and automating measurement validation means you can perform your tests up to 30% faster, giving you more time to focus on other critical tasks and increasing your productivity.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e* 30% faster testing compared to manual testing.\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReduce Documentation and Reporting Time up to 50%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1670 Series Multifunction Installation Testers help you reduce documentation time by up to 50%. Link test results to the circuit or point under test, reducing manual data entry and recordkeeping. You can also preview inspection results in the field via the tester, a smart device, or PC, and Fluke Connect compatibility making it easy to store, manage, and share your data from the field. Fluke TruTest Software lets you generate inspection certificates on site with just a few simple steps, so you can finalize and invoice your inspection at the time of service. The Fluke Connect mobile app enables you to document and input all relevant photos and inspection notes, so you can complete your work on site, eliminating extra work at the office.\u003cbr\u003e\u003cbr\u003e\u003csup\u003e* 50% faster reporting and documentation based on customer interviews.\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation PreTest™️ Functionality\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1674 FC includes a patented Insulation PreTest, so you can better protect the installation and avoid costly mistakes. If the tester detects that appliances are connected to the system during the test, it will stop the insulation test and provide a visual and audible warning. This helps eliminate accidental damage to peripheral equipment and saves you both time and money.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptimised Software and Reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke TruTest Software simplifies electrical system data management and reporting, eliminating the hassle of traditional data management with a single, integrated Fluke solution. Proper data management and testing information is critical for producing easy-to-understand reports for clients or your management team. TruTest streamlines the process by allowing you to create and transfer testing metadata between the software and your installation tester using a USB-C interface cable, or via the Fluke Connect mobile app, which helps you ensure accurate results.\u003c\/p\u003e\n\u003cp\u003eThe user-friendly interface, intuitive workflow, and report builder means that you can quickly format your measurement data into printable test certificates and reports, complete with your company logo and electronic signature. The live onscreen dashboard allows you to see the status of all your clients instantly and navigate to further levels of detail if desired.\u003c\/p\u003e\n\u003cp\u003eFluke TruTest Software allows you to create certificates that are compliant with a growing list of regional reports, including BS7671, DIN VDE 0100-600, ÖVE\/ÖNORM E 8101, NIN\/NIV, NEN3140, and other European installation test standards. All these reports are available at the touch of a button, and a pre-configured international template ensures that no matter your location, TruTest Software has you covered.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke Connect Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnhance the functionality of the 1673 FC and 1674FC Installation Testers with the Fluke Connect mobile app, eliminating tedious data entry and optimizing data management with cloud storage. The Fluke Connect mobile app wirelessly synchronizes measurement data from your installation tester for later export to TruTest desktop software, allowing for prompt and effective reporting even on location. Use the Fluke Connect app to create projects and upload them to your 1673 FC and 1674 FC for streamlined data management. Construct distribution boards and circuits to send to your tester, using this data to guide your testing regime. With the Fluke Connect app, you can also take photos with your smart device and assign them, along with notes, to specific test points or assets, creating detailed visual inspection reports.\u003c\/p\u003e\n\u003cp\u003eWith the powerful Fluke Connect ecosystem of test tools, you’ll be able to take your troubleshooting and reporting to the next level. Connect additional test tools, like the Fluke 369 FC Leakage Current Clamp or the Fluke 1630-2 FC Earth Ground Clamp, to synchronize data between auxiliary devices and test points, providing your clients with a clearer picture of overall facility health.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eField updatable — you can apply any changes to regulations or enhancements to the tester in the field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and lightweight (less than 1.6 kg), with a padded neck strap to free your hands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull-color touch screen and tactile rotary knob for fast navigation, with no complex multi-level menus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRechargeable 2,500 mAh Li-ion battery to cover a full day of testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard USB-C charging Port with fast charging support for convenient on-the-go charging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNewly designed professional hard case for transporting and protecting your installation tester and accessories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional high current loop mode for faster measurements than loop tests with non-trip mode for RCD protected circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Monitoring Devices (IMD) tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSurge Protection Device (SPD) functional test.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage drop measurement function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZ Max memory for loop tests to support easy evaluation of the highest loop test value.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnique zero adapter for fast, reliable, and accurate test lead and mains cord compensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous readings of voltage measurements between L-N, L-PE, and N-PE using the mains cord. No need to change measurement connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD trip current and trip time measurement in parallel (RCD type AC, A, B, F and GFCI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePEFC or PSC and loop impedance measurement in parallel, displays them together on the dual display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRing testing lets you select the required input sockets without exchanging test leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity test with low test current (10 mA) to measure motor windings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth Volt Touchpad detects raised earth voltages \u0026gt; 50 V, indicating potentially dangerous situations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSimple bidirectional user interface eliminates complex multi-level menus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasy setup with the full-color touch screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast, accurate testing with Auto Test and Automatic Measurement Validation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluke Connect™ compatibility eliminates tedious data entry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreview results and generate certificates on site with Fluke TruTest™ software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eContents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMultifunction installation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy duty mains cord with single input connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHard case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUSB-C Power adapter for charging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote control probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHanging strap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest leads and probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLi-Ion battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eFluke TruTest Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e26.25 cm x 14.19 cm x 11.93 cm (10.3 in x 5.6 in x 4.7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (incl. batteries)\u003c\/td\u003e\n\u003ctd\u003e1.6 kg (3.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery size, quantity\u003c\/td\u003e\n\u003ctd\u003eBP290, Li-ion, 10.8 V, 2500 mAh, 27 Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC\/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V, CAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003eIEC 61557-1 to IEC\/EN 61557-8 and IEC 61557-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eVoltage measurement AC, DC, and frequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e320 kΩ\u003c\/td\u003e\n\u003ctd\u003e660 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e45-66 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e320 kΩ\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eContinuity testing (R\u003csub\u003eLO\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange (Auto ranging)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 Ω\/200 Ω\/2000 Ω\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\/0.1 Ω\/1 Ω\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eInsulation resistance measurement (R\u003csub\u003eISO\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eTest voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e1672\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100-250-500-1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e1673 FC\/1674 FC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50-100-250-500-1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 MΩ\u003cbr\u003e20 MΩ to 100 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003cbr\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 MΩ\u003cbr\u003e20 MΩ to 200 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003cbr\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 MΩ\u003cbr\u003e20 MΩ to 200 MΩ\u003cbr\u003e200 MΩ to 500 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003cbr\u003e0.1 MΩ\u003cbr\u003e1 MΩ\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 200 MΩ\u003cbr\u003e200 MΩ to 1000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003cbr\u003e1 MΩ\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eInsulation pretest\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation safety pretest\u003c\/td\u003e\n\u003ctd\u003eConnections from the Tester to L, N, and PE are required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003cstrong\u003eInsulation pretestSurge Protection Device (SPD) Insulation RAMP Test (Varistor Test) IEC 61643-11\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003eStep Ramp 0 V to 500 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eStep Ramp 0 V to 1000 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Monitoring Devices (IMD) IEC 61557-8\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 kΩ to 10 kΩ\u003c\/td\u003e\n\u003ctd\u003e1 kΩ\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cbr\u003e\u0026gt; 1 MΩ only available with voltages \u0026gt;100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 kΩ to 100 kΩ\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 Ω to 3 MΩ\u003c\/td\u003e\n\u003ctd\u003e100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eLoop and line impedance (ZI No Trip and Hi Current)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy[1]\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 Ω\u003csup\u003e[2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω\u003c\/td\u003e\n\u003ctd\u003eHi Current mΩ mode: ± (2 % + 35 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 Ω\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd\u003eNo Trip (2\u0026amp;3 wire) mode: ± (3 % + 6 digits)\u003cbr\u003eHi Current mode: ± (2 % + 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd\u003eNo Trip mode: ± (3 %)\u003cbr\u003eHi Current mode: ± (2 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003ctd\u003e± 6 %\u003csup\u003e[3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003col\u003e\n\u003cli value=\"NaN\"\u003eValid for resistance of neutral circuit \u0026lt; 20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eFluke Connect™ 1674 FC model only.\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eValid for mains voltage \u0026gt; 200 V.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eProspective Earth Fault Current (PEFC) Prospective Short Circuit Current (PSC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e0 kA to 50 kA\u003c\/td\u003e\n\u003ctd\u003eI\u003csub\u003eK\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 1000 A\u003cbr\u003eI\u003csub\u003eK\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≥ 1000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003cbr\u003e0.1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eComputation: Prospective Earth Fault Current (PEFC\/I\u003csub\u003eK\u003c\/sub\u003e) or prospective short circuit current (psc\/I\u003csub\u003eK\u003c\/sub\u003e) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eVoltage drop (by line impedance test)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003e0.0-99.9%\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003eConsider accuracy of line\u003cbr\u003eimpedance measurement(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNote: Voltage drop reading is calculated from line impedance measurement \u0026amp; entered current rating\u003cbr\u003e\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eRCD tests, RCD types tested\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eRCD Type\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1672\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1673 FC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1674 FC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\u003csup\u003e[2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eG\u003csup\u003e[3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003eS\u003csup\u003e[4]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003csup\u003e[5]\u003c\/sup\u003e, F\u003csup\u003e[6]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA, F\u003c\/td\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB, B+\u003csup\u003e[7]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB, B+\u003c\/td\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRDC-DD, RCD A\/EV, RCD B\/Mi\u003csup\u003e[8]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGFCI\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003col\u003e\n\u003cli value=\"NaN\"\u003eRCD test inhibited for V \u0026gt; 265 AC\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eRCD tests permitted only if the selected current, multiplied by earthing resistance, is \u0026lt; 50 V.\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eAC – Responds to AC\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eG – General, no delay\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eS – Time delay\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eA – Responds to AC and pulsed signal\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eF – responds to AC, pulsed and high frequency\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eB, B+ – Responds to AC, pulsed, high frequency, and smooth DC\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eRDC-DD – Responds to residual currents of 6 mA DC\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eRCD tripping time test (ΔT)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cbr\u003e\u003cstrong\u003eTest Function\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e\u003cstrong\u003eRCD Current Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 mA\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e300 mA\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e500 mA\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 mA\u003csup\u003e[2]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVar\u003csup\u003e[3]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ex½, 1\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ex\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e•\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMains voltage 50 V – 265 V ac, 45\/66 Hz\u003c\/p\u003e\n\u003col\u003e\n\u003cli value=\"NaN\"\u003eType B RCDs require mains voltage range of 195 V to 265 V.\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eType AC RCDs only.\u003c\/li\u003e\n\u003cli value=\"NaN\"\u003eType A RCDs are limited to 700 mA, not available for Type B RCDs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eRCD Tripping Current (I\u003csub\u003eΔN\u003c\/sub\u003e) Measurement\/Ramp Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cbr\u003e\u003cstrong\u003eCurrent Range\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cbr\u003e\u003cstrong\u003eStep Size\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDwell Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType G\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 % to 110 % of RCD-rated current\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e10 % of I\u003csub\u003eΔN\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e[2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e300 ms\/step\u003c\/td\u003e\n\u003ctd\u003e500 ms\/step\u003c\/td\u003e\n\u003ctd\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e     1. Specified trip current ranges (IEC 61008-1):\u003c\/p\u003e\n\u003cdiv\u003e         30 % to 150 % for Type A IΔ N \u0026gt; 10 mA\u003cbr\u003e         30 % to 210 % for Type A IΔ N = 10 mA\u003cbr\u003e         20 % to 210 % for Type B\u003cbr\u003e         50 % to 100 % for Type AC\u003cbr\u003e         35 % to 140 % for Type A (\u0026gt; 10 mA)\u003cbr\u003e         35 % to 200 % for Type A (£ 10 mA)\u003cbr\u003e         50 % to 200 % for Type B\u003c\/div\u003e\n\u003cdiv\u003e    2. 5 % for Type B\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEarth resistance test (RE) 1673 FC and 1674 FC only\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 Ω\/2000 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\/1 Ω\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003ctd\u003e25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003ePhase sequence indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Sequence indicator is active\u003c\/td\u003e\n\u003ctd\u003e185 V to 600 V\u003c\/td\u003e\n\u003ctd\u003e“1-2-3”: or “3-2-1” for incorrect phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44426714480796,"sku":"FLUFLK-1673FC-TRUTEST","price":4300.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/6169\/7948\/files\/87f5f1d6-1270-4184-9ff5-b307015424d2_product_slideshow_main.jpg?v=1773796684","url":"https:\/\/mektronics.com.au\/products\/fluke-1673-fc-aus-ftt-installation-tester-aus-trutest","provider":"Mektronics Australia","version":"1.0","type":"link"}